Simpson 260-8XPI Specification
|
DC VOLTAGE |
Ranges |
250mV, 1V, 2.5V, 10V, 25V, 50V, 250V, 500V, 1000V |
Accuracy |
2% of full scale |
Sensitivity |
20K per volt |
AC VOLTAGE |
Ranges |
2.5V, 10V, 25V ,50V, 250V, 500V, 1000V |
Accuracy |
3% of full scale |
Sensitivity |
5K per volt |
DECIBEL |
5 Ranges |
-20 to +50dB |
Reference |
0dB= 1mW into 600Ω |
DC CURRENT |
Ranges |
50μA, 1mA, 10mA, 100mA, 500mA, 10A |
Accuracy |
1.5% full scale 5OμA, 2.0% of full scale, all other |
Voltage Drop: (Nominal) |
250 mV on 50μ, A/1mA, 255mV on 10mA/10A, 300mV on 100mA, 500mV on 500mA |
RESISTANCE |
Ranges |
Rx 1, Rx 100, Rx 10K |
Accuracy |
2.5° of arc on Rx1, 2.0° of arc on other |
Maximum Indication |
0-2KΩ, 0-200Ω, 0-20MΩ |
General Specifications |
Batteries |
1.5 V AA, 9V (NEDA No. 13F, 1604A) |
Fuse |
F1 1A, 250V, type 3AG, quick acting Littelfuse® Type 312001; F2 2A, 600V Littelfuse® Type BLS or 2A 600V, Bussman® Type BBS. |
Size |
5 1/4" x 7" x 3 1/8" (13.34 x 17.78 x 7.94 cm) |
Weight |
2 1/4 lbs. (1.02 Kg) |
Rated Circuit-To-Ground Voltage |
1000V AC/DC Max |