Display: 3? digit liquid crystal display (LCD) (6600 count) with a 66-segment analog bar-graph Polarity: Automatic, positive implied, negative polarity indication Over range: (OL) or (-OL) is displayed Zero: Automatic Low battery indication: ?? is displayed when the battery voltage drops below the operating level Auto power off: Approx. 30 minutes Backlight: Backlight auto-off approx. 60 sec. Measurement rate: 2.8 times per second, nominal Analog bar-graph: 28 times per second Operating environment: 0?C to 50?C (32?F to 122?F) at 70% R.H. Storage temperature: -20?C to 60?C (-4?F to 140?F) at 80% R.H. with battery removed from meter Temperature Coefficient: 0.1 ? (specified accuracy) per ?C. (0?C to 18?C, 28?C to 50?C) Environmental: 2000m (6561.7 Feet), Indoor use Jaw opening capability: 57 mm (2.0 in) conductor Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Battery life: Typically 75 hours with carbon-zinc; 150 hour with alkaline Dimensions: 283 x 105 x 50 mm (11.1 x 4 x 2.1 in.) Weight: 559 gm (1.23 lb.) Safety: LVD Meets EN61010-1:2001 and EN61010-2-032:2002, CAT III 1000V, CAT IV 600V, class II and pollution degree 2 EMC: EN 61326-1:2006 This product complies with requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. |