Ground Fault Sensors-Fixed

 
NK AGT3-420-24L-FL - Ground Fault Indicator, 0-200 mA Range, Top Terminals
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: No
  • Mechanical Relay Output: No
  • Solid State Relay Output: No

List Price: $275.00

Your Price: $244.75

Sign-in for EDU Pricing!

In Stock:
  • View Payment Options
NK AGV3-SDT-120-DEN-TR3 - AGV Series Ground Fault Relay
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $784.00

Your Price: $697.76

Sign-in for EDU Pricing!

In Stock:
NK AGV3-SDT-120-ENE-TR3 - AGV Series Ground Fault Relay
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $784.00

Your Price: $697.76

Sign-in for EDU Pricing!

In Stock:
NK AGV3-SDT-120-LA-TR3 - AGV Series Ground Fault Relay
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $796.00

Your Price: $708.44

Sign-in for EDU Pricing!

In Stock:
NK AGV3-SDT-24U-DEN-TR3 - AGV Series Ground Fault Relay
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $734.00

Your Price: $653.26

Sign-in for EDU Pricing!

In Stock:
NK AGV3-SDT-24U-ENE-TR3 - AGV Series Ground Fault Relay
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $734.00

Your Price: $653.26

Sign-in for EDU Pricing!

In Stock:
NK AGV3-SDT-24U-LA-TR3 - Ground Fault Relay, Max Wire Bundle 0.75 in (19.1 mm) Dia
  • Style (Ground Fault Sensor): Fixed Core
  • Fixed Response Time: No
  • Adjustable Response Time: Yes
  • Set Points: Yes
  • Mechanical Relay Output: Yes
  • Solid State Relay Output: No

List Price: $765.00

Your Price: $680.85

Sign-in for EDU Pricing!

In Stock:
null
null
null
null
null
null
null

Recommended for you

Ground Fault Sensors-Fixed

Ground Fault Sensors help protect people, products, and processes from damage by ground fault conditions by monitoring all current-carrying conductors in grounded systems.  Using the “Zero Sum” Operating Principle, as soon as current leaks to ground (fault condition) the two currents become imbalanced and a net magnetic field results. These sensors monitor this field and trip alarm contacts when the leakage rises above a set point.
 
Ground fault sensors are used in a variety of applications, including personal protection and equipment protection. They come in a variety of sizes and styles to meet a range of needs.
 
Ground Fault Sensors Applications
  • Personal protection:
  • Equipment Protection
  • Eliminate nuisance tripping
  • Meets requirements as stipulated by governmental and industrial regulatory groups for ground fault sensing
  • Replace bulky two-piece sensor solutions that require separate CTs or relay modules
  • Use with shunt trip breakers to provide total ground fault protection to sensitive machine electronics.
  • Detect ground faults in resistance/impedance heating, industrial automation and control, theatrical lighting, portable power distribution, and snow melt/heat trace applications
  • Sense progressive levels of ground fault in motors or heating systems to detect deterioration prior to catastrophic failure.
Key Features of Ground Fault Sensors to Consider
  • N.O./N.C. solid-state switch or mechanical relay outputs
  • Normally energized or normally de-energized contacts
  • Noise Immunity option for use in EMI/RFI sensitive environments
  • Applicable on single- and three-phase systems
  • Ideal for use with shunt trip breakers
  • Magnetically isolated from monitored circuit and control power.
  • UL, CE approved
  • Finger-safe Terminals for Worry-free Installation and Operation
  • Uses “Zero Sum” Operating Principle to reliably sense imbalance in magnetic fields associated with current leakage to ground
X