MadgeTech Dataloggers for Environmental Variables

 
MadgeTech DHS - Dry Heat Sterilization Data Logging System
Catalog: 900002-00
  • Type (Temperature): RTD
  • Power Source: Battery
  • Battery Life: 1 YEARS (8760 HRWhat's This?)
  • Input Source (Probe): External Probe
  • Accuracy: ±1.2 °C (-200 °C to +400 °C)
  • LCD Screen: No

Your Price: $3,000.00

Sign-in for EDU Pricing!

In Stock:
  • View Payment Options
MadgeTech EggTemp - Egg Temperature data logger
Catalog: 900088-00
  • Max Temperature: 140 F (60 CWhat's This?)
  • Min Temperature: 32 F
  • Power Source: Battery
  • Battery Life: 1 YEARS (8760 HRWhat's This?)
  • Software Included: Yes
  • Safety Approval: CE

Your Price: $249.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech EggTemp-RH - Egg Temperature and Humidity Data Logger
Catalog: 900091-00
  • Max Temperature: 140 F (60 CWhat's This?)
  • Min Temperature: 32 F
  • Power Source: Battery
  • Battery Life: 1 YEARS (8760 HRWhat's This?)
  • Software Included: Yes
  • Safety Approval: CE

Your Price: $269.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech Element CO2 - Temperature and Humidity Datalogger
Catalog: 901391-A7
  • Max Temperature: 131 F (55 CWhat's This?)
  • Min Temperature: 32 F
  • Power Source: Battery
  • Battery Life: 11680 HR
  • Input Source (Probe): External Probe
  • Accuracy: ±1 °C

Your Price: $769.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech Element HT - Wireless Temperature and Humidity Datalogger
Catalog: 901423-A7
  • Type (Temperature): RTD
  • Max Temperature: 140 F (60 CWhat's This?)
  • Min Temperature: -4 F
  • Power Source: Battery
  • Battery Life: 26280 HR
  • LCD Screen: Yes

Your Price: $229.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech ETR101A - Exhaust temperature recording system
Catalog: 900098-00
  • Type (Temperature): K
  • Max Temperature: 176 F (80 CWhat's This?)
  • Min Temperature: -40 F
  • Power Source: Battery
  • Battery Life: 87600 HR
  • Accuracy: ±2°C

Your Price: $369.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech Event101A - Event Recorder, Input range of up to 30 V with a storage capacity up to 838,041 readings
Catalog: 900103-00
  • Max Temperature: 176 F (80 CWhat's This?)
  • Min Temperature: -40 F
  • Power Source: Battery
  • Battery Life: 87600 HR
  • Safety Approval: CE
  • Interfaces I/O: USB

Your Price: $99.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech HiTemp140-10 - 140 Degrees C Temperature Data Logger with a 10-inch Probe
Catalog: 902109-00
  • Type (Temperature): Other
  • Max Temperature: 500 F (260 CWhat's This?)
  • Min Temperature: -328 F
  • Power Source: Battery
  • Battery Life: 2 YEARS (17520 HRWhat's This?)
  • Input Source (Probe): External Probe

Your Price: $579.00

Sign-in for EDU Pricing!

In Stock:

As low as: $569.00

In Stock:

To add to cart or request a quote.

MadgeTech HiTemp140-FP-12 - Data Logger with a 6 inch or 12 inch flexible RTD probe
Catalog: 900211-00
  • Type (Temperature): RTD
  • Max Temperature: 500 F (260 CWhat's This?)
  • Min Temperature: -76 F
  • Power Source: Battery
  • Battery Life: 8760 HR
  • Input Source (Probe): External Probe

Your Price: $589.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech HiTemp140-FP-24 - 140°C Temperature Logger with 24-inch Flex RTD Probe with Steel Tip
Catalog: 902364-00
  • Type (Temperature): Other
  • Max Temperature: 500 F (260 CWhat's This?)
  • Min Temperature: -328 F
  • Power Source: Battery
  • Battery Life: 2 YEARS (17520 HRWhat's This?)
  • Input Source (Probe): External Probe

Your Price: $539.00

Sign-in for EDU Pricing!

In Stock:

Your Price: $539.00

Sign-in for EDU Pricing!

In Stock:
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Dataloggers for Environmental Variables

Environmental Datalogger (or Data Logger, Data Recorder, Data Acquisition) refers to electronics designed to capture environmental variables such as temperature and humidity over time for study and review later.

Benefits of Dataloggers/Data Recorders
  • Quiet, unattended 24/7 operation
  • Simple to setup and operate. Many portable models available
  • Wide variety of measurement types and measurement speeds possible
  • Help troubleshoot and identify problems in many fields
  • Steady declining cost
Parts of a Datalogger/Data Recorder
  • Built in sensor, such as temperature, or electrical terminals to connect an external one
  • A/D or analog to digital converter and signal conditioning electronics
  • Non-volatile storage memory for the collected data and a method to specify the storage rate and on some models the scan interval
  • PC Communications or other method to move the data to a computer and to configure the unit
  • Optionally a local display and keypad. Not always needed, so “blind” units are a cost saving
My handheld Digital Thermometer logs so is it considered a Datalogger?

For our website purposes, no. We further classify data logging instruments as dedicated to data logging. Typically they will be “blind”, i.e. no display or buttons, and intended for long term unattended operation. A handheld digital thermometer will have a host of other features, one of which may optionally be to record data. We have categorized these measuring instruments here Products > Thermometers.
 