Power Meter |
Power Meter Detector Type |
InGaAs |
Power Meter Dynamic Range |
+5 to -77 dB (CATV +25 to -57 dB) |
Auto Test Range |
0 to - 36 dB |
Calibrated Wavelengths |
850, 1300, 1310, 1490, 1550, 1625 nm |
Units of Measurement |
dBm, dB |
Resolution |
0.01dB |
Power Measurement Uncertainty |
± 0.18 dB under reference conditions, ± 0.25 dB from 0 to -65 dBm,
± 0.35 dB from 0 to +5 dBm and from -65 to -77 dBm |
Modulation Modes Detected |
CW, 270 Hz, 1000 Hz, 2000 Hz |
Light Source |
Laser Output Power |
0 dBm, 1mw |
Output Stability |
± .05 dB / 24 hrs @ constant temp,, ± .02 dB/C temperature coefficient |
Laser Wavelengths Available |
850/1300/1310/1490/1550 and 1625nm (± 20 nm) |
Transmitted Modulation Modes |
CW, 270 Hz, 1000 Hz, 2000 Hz |
Laser Safety Classification |
Class I safety per FDA/CDRH and IEC-825-1 regulation |
Spectral Width |
<3nm typ. |
Optical Return Loss Meter |
Optical Return Loss Dynamic Range |
0-60 dB |
ORL Wavelengths |
1310/1490/1550/1625nm |
Optical Return Loss Accuracy |
± .05 dB @ a -55db reflection |
Resolution |
0.01 dB |
Spectral Width (RMS) |
<5nm |
Connector |
FC/APC or SC/APC |
General Specifications |
Display |
4 in Color Touch Screen |
Storage Locations |
5000 |
Battery/Operating Time |
Li-Poly / 12 hrs typ. |
Power Requirements |
Micro USB 5V 1.2A |
Operating Temperature Range |
-10 to 45 C |
Dimensions |
6.25" L x 4.125" W x 1.875" H (159mm L x 105mm W x 48mm H) |
Weight |
1.5 lbs. |