Basic DC accuracy | 0.05% |
Compare | Compares stored value with measured value for matching components |
Data Hold | Enables the reading on the display to be frozed. The two hold system hold the previous reading when a new one is recieved |
Relative | Display a measured value as a percentage of a stored value. Useful for component testing. |
Record | Record Minimum, Maximum, and average reading. |
Auto Range | Automatically selects the best range for measurement |
Continuity & Buzzer | Check for opens and shorts |
RS232 | Optically isolated software optional |
Safety | Designed to meet cULus 3111 and IEC1010 |
LCD | Large 50,000 count display |
Triple Display | Shows more than one reading simultaneously |
Bar Graph | 51 Segments Analog Bar Graph to catch fast AC fluctuations |
Back Light | Allows viewing in any light condition |
True RMS | Needed to accurately measure ninsinusoidal AC voltage and current waveforms found on controls and cicuits |
Test Leads | Silicone rubber 1,000 CAT III, 600V CAT IV, 10A |
Auto Power Off | DMM will automatically power down after approximately 15 minutes of inactivity to extend battery life. Disable Auto Power Off: Hold down the REC button and turn the meter on |
Diode Test | Displays approximate forward bias voltage |
GENERAL SPECIFICATIONS |
Weight | 530g |
Operating Temp | 0?C to 45?C (-32?F to 113?F) |
Storage Temp | -20?C to 60?C (-40?F to 140?F) |
Relative Humidity | 0% to 80%: (0?C to 35?C/32?F to 95?F) |
0% to 70% | (45?C to 55?C/95?F to 131?F) |
Temp Coefficient | 0.1x (Specified Accuracy) per ?C for temperature <18?C to >28?C |
Power Supply | 9 Volt Alkaline Battery |
OPTIONAL ACCESSORIES | 9 Volt Alkaline Battery |
OPTIONAL ACCESSORIES |
A100 | Carrying Case |
A191 | RS232 cable & software for optically isolated IR port |
A251 | AC Clamp-On Accessory for DMMs 0-400 Amps |
A254 | Low Current AC/DC Adapter for DMMs 10 Amp range, 0.001 resolution 60 Amp range, 0.01 resolution |
A256 | AC/DC Clamp-On Accessory for DMMs 0.1 A resolution |
A296 | AC/DC Clamp-On Accessory for DMMs 0-1,000 Amps |
A301 | Temperature Adapter with GK11M and battery, 0.1?C or ?F resolution |
A620 | 500psi Pressure/Vacuum Adapter for DMMs |
Specification | 190 (resolution) | 192 (resolution) | 194 (resolution) |
AC Volts | Max. reading Frequency Best resolution | 750 (45Hz to 20kHz) (0.0001V) | 750 (45Hz to 20kHz) (0.0001V) | 750 (45Hz to 20kHz) (0.0001V) |
DC Millivolts | Max. reading Best resolution | 500 (0.0001mV) | 500 (0.0001mV) | 500 (0.0001mV) |
DC Volts | Max. reading Best resolution | 1,000 (0.0001V) | 1,000 (0.0001V) | 1,000 (0.0001V) |
DC Microamps | Max. reading Best resolution | 5,000 (0.01uA) | 5,000 (0.01uA) | 5,000 (0.01uA) |
DC Milliamps | Max. reading Best resolution | 500 (0.001mA) | 500 (0.001mA) | 500 (0.001mA) |
DC Amps | Max. reading Best resolution | 10 (0.0001A) | 10 (0.0001A) | 10 (0.0001A) |
AC Microamps | Max. reading Best resolution | 5,000 (0.01uA) | 5,000 (0.01uA) | 5,000 (0.01uA) |
AC Milliamps | Max. reading Best resolution | 500 (0.001mA) | 500 (0.001mA) | 500 (0.001mA) |
AC Amps | Max. reading Best resolution | 10 (0.0001A) | 10 (0.0001A) | 10 (0.0001A) |
Ohms | Max. reading Best resolution | 500 (0.01 ohm) | 500 (0.01 ohm) | 500 (0.01 ohm) |
Kohms | Max. reading Best resolution | 500 (0.0001 Kohm) | 500 (0.0001 Kohm) | 500 (0.0001 Kohm) |
Mohms | Max. reading Best resolution | 50 (0.0001 Mohm) | 50 (0.0001 Mohm) | 50 (0.0001 Mohm) |
Frequency Hz | Max. reading Best resolution | 500 (0.001Hz) | 500 (0.001Hz) | 500 (0.001Hz) |
Frequency kHz | Max. reading Best resolution | 500 (0.0001kHz) | 500 (0.0001kHz) | 500 (0.0001kHz) |
Inductance mH | Max. reading Best resolution | no | 100 (0.01) | no |
Capacitance Nano Farads | Max. reading Best resolution | no | 500 (0.01) | no |
Capacitance Micro Farads | Max. reading Best resolution | 20,000 (0.001) | 100 (0.001) | 20,000 (0.001) |
Safety | | CAT II 1,000V CAT III 600V | CAT II 1,000V CAT III 600V | CAT III 1,000V CAT IV 600V |
Fuse | | 600V 500mA 600V 10A | 600V 500mA 600V 10A | 1000V 440mA 1000V 11A |