Siglent SPS5043X Specifications |
Output Channels |
1 |
Rated Output Voltage |
40V |
Rated Output Current |
90A |
Total Rated Output Power |
1080W |
Power Ratio |
3.33 |
C.V MODE |
Line Regulation |
18mV (From 90 ~ 132Vac or 170 ~ 265Vac, constant load) |
Load Regulation |
20mV (From No load to Full load, constant input voltage) |
Ripple and Noise (*1) |
(Noise Bandwidth 20MHz; Ripple Bandwidth 1MHz) |
P-P Ripple |
100mV |
RMS Ripple |
14mV |
Voltage Programming Accuracy |
0.1% ± 10mV |
Voltage Programming Resolution |
1mV |
Voltage Readback Accuracy |
0.1% ± 20mV |
Voltage Readback Resolution |
1mV |
Temperature Coefficient |
100ppm/°C from rated output voltage following 30-minute warm-up |
Remote Compensation
Voltage (single wire) |
0.6V |
Rise Time (10% ~ 90% of rated output voltage, rated resistance load) |
Rated load 50mS;
No load 50mS |
Fall Time (90% ~ 10% of rated output voltage, rated resistance load) |
Rated load 50mS;
No load 500mS |
Transient Response Time |
1mS (Time for recovery to within 0.1% + 10mV of its rated output against current of 50% ~ 100%) |
C.C MODE |
Line Regulation |
110mA |
Load Regulation |
110mA |
Ripple and Noise |
216mA |
Current Setting Accuracy |
0.1% ± 100mA |
Current Programming Resolution |
1mA |
Current Readback Accuracy |
0.1% ± 100mA |
Current Readback Resolution |
1mA |
Temperature Coefficient |
200ppm/°C from rated output current following 30-minute warm-up |
Protection Function |
OVP |
Setting Range |
4~44V |
Setting Accuracy |
± (2% of rated output voltage) |
OCP |
The maximum output current limit of the front output terminal is 10A |
Setting Range |
9~90A |
Setting Accuracy |
± (2% of rated output current) |
OTP |
Over temperature alarm and shut off output |
Low AC Input Protection |
Shut off output |
LPP |
The over power limit is approximately 105% of the rated output power |
Rising/Falling Voltage Slew Rate: Only applicable if V-I Mode is set to CV Slew Rate Priority |
|
0.1~80V/s |
Rising/Falling Current Slew Rate: Only applicable if V-I Mode is set to CC Slew Rate Priority |
|
0.01~180.00A/s |
Output Resistance Setting |
|
0~0.5Ω |
Efficiency |
100Vac |
>77% |
200Vac |
>79% |
*1: Use (1:1) probe to measure at the positive and negative poles of sense terminal. |
Series and Parallel Capability |
Parallel |
3 |
Series |
2 |
Channels in Series and Parallel |
None |
Analog Programming and Monitoring |
External Voltage Control of the Voltage Output |
Accuracy: +0.5% of rated output voltage |
External Voltage Control of the Current Output |
Accuracy: +1% of rated output current |
External Resistance Control of the Voltage Output |
Accuracy: +1.5% of rated output voltage |
External Resistance Control of the Current Output |
Accuracy: +1.5% of rated output current |
Output Voltage/ Current Monitor Accuracy |
±1% |
Shutdown Control |
Close output with LOW (0V~0.5V) or short circuit |
Output On/Off Control |
Use LOW (0V~0.5V) or short circuit to turn on the output
Use HIGH (4.5V~5V) or open circuit to turn off the output |
CV/CC/ERR/
ON/OFF Status |
Photo coupler open collector output; Maximum voltage 30V, maximum sink current
8mA |
Input Characteristics |
Normal Rated Input |
100Vac ~ 240Vac, 50Hz ~ 60Hz, Single-phase |
Input Voltage Range |
90Vac ~ 265Vac |
Input Frequency Range |
47Hz ~ 63Hz |
Maximum Input Current of Different Power Models |
1080W |
100Vac |
15A |
200Vac |
7.5A |
Surge Current |
<75A |
Maximum Input Power |
1500VA |
Power Factor |
|
100Vac |
0.99 |
200Vac |
0.98 |
Hold-up Time |
≥20mS |
Interface Capability |
USB |
Type A: HOST, Type B: DEVICE, SPEED: 1.1/2.0 |
LAN |
MAC address, Gateway IP address, Instrument IP address, Subnet Mask |
GPIB |
Optional: USB-GPIB adapter |
Environment Condition |
Operating Temperature |
0˚C ~ 50˚C |
Storage Temperature |
-25˚C ~ 70˚C |
Operating Humidity |
20% ~ 85% RH; No condensation |
Storage Humidity |
90% RH or less; No condensation |
Altitude |
≤ 2000m |
General Specifications |
Weight (host only) |
16.53 lbs |
Dimensions (WxHxD) |
8.43" x 4.88" x 16.46" |
Cooling |
Internal fan forced air cooling |
EMC |
Class A test and measurement products in compliance with European EMC
Directive 2014/30/EU |
Withstand Voltage |
Input to Base: 1500VAC for 1 minute without abnormality |
Input to Output: 3000VAC for 1 minute without abnormality |
Output to Base: 500VDC for 1 minute without abnormality |
Insulation Resistance |
Input to Base: 500VDC, ≥100m Ω |
Input and Output: 500VDC, ≥ 100m Ω |
Output to Base: 500VDC, ≥100m Ω |