Technical Specification: |
Ground Continuity |
Display Range |
0.00Ω to 199Ω |
Measuring Range |
0.01Ω to 199Ω |
Accuracy |
2% + 5 digits |
Resolution |
0.01Ω maximum |
Open Circuit Test Voltage |
4VDC, nominal |
Test leads zero |
Zero up to 10 Ω, by Zero button |
Test Lead Compensation |
Null out up to 10Ω |
Number of measurements |
5,000 1 second tests |
Audible / visible warning |
≥ 30VAC/DC at inputs |
User Protection |
Warning and test inhibited if ≥ 30VAC/DC at inputs |
Insulation Resistance (auto short circuit test) |
Display Range |
0.1MΩ to 20MΩ |
Measuring Range |
0.1MΩ to 20MΩ |
Accuracy |
5% + 5 digits |
Resolution |
0.1MΩ maximum |
Open Circuit Test Voltage |
250V, 500V, 1000VDC (as per IEC 61557-2) |
Test current |
1mA nominal as per IEC 1557-2 |
Short circuit test current |
<2mA |
Number of measurements |
5,000 1 second tests |
Audible / visible warning |
≥ 30VAC/DC at inputs |
User protection |
Test inhibited if ≥ 30VAC/DC at inputs |
Insulation resistance (point to point) |
Display Range |
0.05MΩ to 300MΩ |
Measurement range |
0.05MΩ to 300MΩ |
Accuracy |
5% + 5 digits |
Resolution |
0.01MΩ maximum |
Open circuit test voltage |
250, 500, 1000V (as per IEC 61557-2) |
Short circuit test current |
<1mA |
Number of measurements |
5,000 1 second tests |
Audible / visible warning |
≥ 30VAC/DC at inputs |
Circuitry protection |
Test inhibited if ≥ 30VAC/DC at inputs |
Voltage measurement (via 4mm probes) |
Display Range |
30V – 440VAC/DC |
Measurement Range |
30V – 440VAC/DC |
Resolution |
1V |
Accuracy |
±(5%+2d) |
Vo/c voltage measurement (via PV test leads) |
Display range |
0.0V – 1000VDC |
Measurement range |
5.0V – 1000VDC |
Resolution |
0.1V |
Accuracy |
±(0.5%+2d) |
Enunciators |
DC voltage polarity correct or reversed |
Is/c current measurement (via PV test leads) |
Display range |
0.0A – 15.0ADC |
Measurement ranges |
0.5A – 15.0ADC |
Resolution |
0.1A |
Accuracy |
±(1%+2d) |
Operating current (via DC current clamp) |
Display range |
0.0A – 40.0A AC/DC |
Measurement ranges |
0.1A – 40.0A AC/DC |
Resolution |
0.1A |
Accuracy |
±(5% + 2 digits) |
DC power |
Display range |
0.0W – 40.0kW |
Measurement ranges |
10W – 40.0kW |
Resolution |
10W max |
Accuracy |
±(6% + 2 digits) |
I-V curve |
Voltage measurement range |
5.0V – 1000V |
Voltage measurement accuracy |
±(0.5%+2d) |
Current measurement range |
0.5A – 15.0A |
Current measurement accuracy |
1% |
Power measurement range |
5W – 15kW |
Power measurement accuracy |
2% |
General Specifications |
Case dimensions and weight |
Weight |
2.3 lbs (unit) |
Dimensions |
10.4 x 4.2 x 2.3" |
Display |
Custom LCD with backlight |
Power source |
6 x 1.5V AA cells |
Battery life |
>1000 test sequences |
Auto power down |
User programmable |
Onboard memory |
Up to 999 complete test datasets |
Connectivity |
USB download to PC (CSV format)
Wireless ‘SolarlinkTM’ to Survey 200R (range c. 30m / 100ft)
NFC transfer of data to PVMobile Android App
iOS devices not supported |
App compatibility |
Compatible with Android version 4.2 Jelly Bean
iOS devices not supported |
Software compatibility |
Compatible with SolarCert Elements v2 software (English language only) |