SCS Air Ionizer Test Kit
The SCS 770717 Air Ionizer Test Kit includes and utilizes the 770716 Static Sensor to measure the offset voltage (balance) and charge decay of ionization equipment. The Air Ionizer Test Kit also includes a charger used to place a +/- 1000V charge on the conductive plate, making it possible to also measure the discharge times of air ionization equipment per ANSI/ ESD SP3.3 Periodic Verification of Air Ionizers.
The SCS 770716 Static Sensor indicates surface voltage and polarity on objects. The meter has a measurement range of 0 to ±19.99 kV / 1 inch and a measurement accuracy of +/- 5%. It utilizes a chopper-stabilized sensor for use in both normal and ionized environments. The SCS 770716 Static Sensor enclosure is dissipative and features a 7 mm snap and ground cord for bonding to equipment ground. A rotary zero knob sets the zero-reference point with finely tuned precision, and a Hold button allows the user to freeze a displayed measurement for evaluation. A LED range indicator assists with placing the meter at the correct distance from the object being measured.