Model |
RP1001C |
RP1002C |
Current Range |
10mV/A, 100mV/A |
50mV/A, 500mV/A |
DC Accuracy, typical |
100mV/A: ±3% ±50mA
(50mA to 10A peak range)
10mV/A: ±4% ±50mA
(500mA to 40A peak range)
100mV/A: ±15% maximum
(40A peak to 100A peak range) |
500mV/A: ±3% ±20mA
(20mA to 14A peak range)
50mV/A: ±4% ±200mA
(200mA to 100A peak range)
50mV/A: ±15% maximum
(100A peak to 140A peak range) |
Frequency Range |
DC to 300kHz (-3dB) |
DC to 1MHz (-3dB) |
Battery Type and Life, typical |
9V NEDA 1604A, IEC 6LR61
13 hours (1 each) |
9V NEDA 1604A, IEC 6LR61
8 hours (1 each) |
Dimensions |
280mm x 70mm x 32mm |
262mm x 81mm x 36mm |
Max. Conductor Size |
11mm |
10.3mm |
Dual-BNC Coaxial Cable Length |
100cm |
100cm |
Weight |
260g (battery excluded) |
310g (battery excluded) |
Working Temperature |
0° to +50° |
0° to +50° |
Storage Temperature |
-20° to +80° |
-20° to +80° |
Humidity |
0° to +40°, 95% humidity
+40° to +50°, 45% humidity |
0° to +40°, 95% humidity
+40° to +50°, 45% humidity |
Pollution Degree |
2 |
2 |
EC Declaration of Conformity – Low Voltage |
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC
EN 61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.
EN 61010-2-032:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC
EN 61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.
EN 61010-2-032:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
Additional Compliance |
IEC61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.
IEC61010-2-032:1994: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
IEC61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.
IEC61010-2-032:1994: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
Installation (Overvoltage) Category |
CAT III: Equipment in a fixed industrial location (usually permanently connected)
CAT II: Equipment at this level includes appliances, portable tools, and similar products. Equipment is usually cord-connected.
CAT I: Secondary (signal level) or battery operated circuits of electronic equipment. |
CAT III: Equipment in a fixed industrial location (usually permanently connected)
CAT II: Equipment at this level includes appliances, portable tools, and similar products. Equipment is usually cord-connected.
CAT I: Secondary (signal level) or battery operated circuits of electronic equipment. |
Pollution Degree |
A measure of the contaminates that could occur in the environment around and within a product. Products should be used only in the environment for which they are rated.
Pollution Degree 1:
No pollution or only dry, nonconductive pollution occurs. Products in this category are generally encapsulated, hermetically sealed, or located in clean rooms.
Pollution Degree 2:
Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation occurs only when the product is out of service. |
A measure of the contaminates that could occur in the environment around and within a product. Products should be used only in the environment for which they are rated.
Pollution Degree 1:
No pollution or only dry, nonconductive pollution occurs. Products in this category are generally encapsulated, hermetically sealed, or located in clean rooms.
Pollution Degree 2:
Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation occurs only when the product is out of service. |