Toll Free: (877) 571-7901
Local: (732) 728-2590
salesteam@tequipment.net
My Account
Sign in to see your member price, rewards, orders, tracking and more.
Why Join? Gain access to exclusive pricing, rewards and more!
Member Pricing & Rewards active
(877) 571-7901
Sales@TEquipment.NET
Member Pricing & Rewards are active.
Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
4 (1 Review) | Catalog: MC3132 | Model: Rigol MC3132
MUX32 Module
Your Price: $477.00
Sign-in for EDU Pricing!
Thank you for your interest! Complete the form below and one of our support engineers will contact you directly to coordinate your product demonstration.
Name
Email Address
Phone Number
Which state are you located in?
Thank you!
We've received your request and will be in touch soon.
🤭 Oops there was an error processing your request. Please contact us by phone, chat or email to set-up your demo.
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
32 channel differential Multiplexer module for use with M300 DAQ System Mainframe and MC3065 DMM module. Configurable for 2 or 4 wire measurements. The M3TB32 is the mating terminal block for this module. MC3132 (32-Channel Multiplexer): All 32 channels switch both HI and LO inputs, thus providing fully isolated inputs to the DMM module. MC3132 is divided into two banks (called A and B) of 16 two-wire channels each. When making 4-wire resistance measurement, the instrument automatically pairs channels of A bank and B bank. All channels are break-before-make. You can close multiple channels on this module only if you have not configured any channel to be part of the scan list. This module can be connected with MC3065 (DMM Module, if MC3065 is currently inserted). Measurement Connections Using External Terminal Blocks M300 provides 6 kinds of terminal blocks to easily connect the signal to be measured to the module. The models of the terminal blocks and corresponding modules are listed in the table below. This section introduces how to use the external block.
Note: for the MC3724, the signal can be connected to the SMB connectors on the module directly. No terminal block is needed. WARNING: Cut off all the power supplies before opening the terminal block or removing the terminal block from the module. 1. Place the terminal block with the front (with the RIGOL caption) facing downward and pull the two latches in the arrow direction in the figure below and press them down. Place the terminal block with the front facing upward and pull the upper cover of the terminal block upward and remove it.
2. Connect the cables for connecting the signal under test according to the labels on the circuit board of the terminal block (for the connecting method, refer to Table 1-1). Pass the binding wires through the two groups of holes as pointed out by the arrows in the figure below to fix the cable connected. Pay attention to the channel or terminal connected to the cable to ensure that the signal connected is correct.
3. Connect the terminal block to the module via interface 1 (the interface definition is in Figure 1-7) on the module and screw down the two screw rods onto the nuts on the module.
4. Close the upper cover of the terminal block.
5. Insert the module with the terminal block into the slot of the mainframe.
Please select a rating star.
Please complete this field.
Email Adrress is not Valid.
Almost there, please complete all required fields
Out of 5
Average Customer Review
View All Reviews
Share your thoughts with other customers
Displaying 1 review
Most Helpful First | Newest First
Recommend to a Friend
works nice (so far at least) for RTD readout
4.0
We bought an M301 and MC3132 for the purpose of reading out 16 RTD's with 4-wire connection. This seems to work just fine, we're happy with the system, plan to expand to 64 RTD's in the near future. Caveat: We have not much experience with it yet and still have to complete the software for remote operation, but I don't expect any serious difficulty.
Verified Purchase gv on Apr 16, 2020 I found this helpful (0)