Toll Free: (877) 571-7901
Local: (732) 728-2590
salesteam@tequipment.net
My Account
Sign in to see your member price, rewards, orders, tracking and more.
Why Join? Gain access to exclusive pricing, rewards and more!
Member Pricing & Rewards active
(877) 571-7901
Sales@TEquipment.NET
Member Pricing & Rewards are active.
Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Catalog: M3TB32 | Model: Rigol M3TB32
32 channel MUX Terminal Box
Your Price: $74.00
Sign-in for EDU Pricing!
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
Terminal block accessory for M300 DAQ system modules with model numbers ending in 32. Measurement Connections Using External Terminal Blocks M300 provides 6 kinds of terminal blocks to easily connect the signal to be measured to the module. The models of the terminal blocks and corresponding modules are listed in the table below. This section introduces how to use the external block.
Note: for the MC3724, the signal can be connected to the SMB connectors on the module directly. No terminal block is needed. WARNING: Cut off all the power supplies before opening the terminal block or removing the terminal block from the module. 1. Place the terminal block with the front (with the RIGOL caption) facing downward and pull the two latches in the arrow direction in the figure below and press them down. Place the terminal block with the front facing upward and pull the upper cover of the terminal block upward and remove it.
2. Connect the cables for connecting the signal under test according to the labels on the circuit board of the terminal block (for the connecting method, refer to Table 1-1). Pass the binding wires through the two groups of holes as pointed out by the arrows in the figure below to fix the cable connected. Pay attention to the channel or terminal connected to the cable to ensure that the signal connected is correct.
3. Connect the terminal block to the module via interface 1 (the interface definition is in Figure 1-7) on the module and screw down the two screw rods onto the nuts on the module.
4. Close the upper cover of the terminal block.
5. Insert the module with the terminal block into the slot of the mainframe.