Sample Method |
Sample draw pump, flow rate 0.45 LPM, 50 foot sample range |
Display |
Digital LCD, auto backlight, peak bar display, auto display rotation, and customize order of gases |
Audible Alarm |
95 dB at 1 ft. |
Languages |
English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian |
Continuous Operation |
14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.
8 hours Alkaline battery pack (3 AA size within each pack) |
Operating Temperature and Humidity |
-4°F to 122°F (-20°C ~ +50°C), 0- 95% RH non condensing |
Dimensions |
2.6" W x 7.8" H x 2" D (H200 x W68 x D52 mm)
14 ounce (400g) (with lithium battery pack) |
Case Material |
Dust and water resistant with IP-67 approval
(exclude sample hose and probe) |
Safety Design / Approvals |
Explosion proof: IECEx, ATEX, TIIS, cCSAus
Explosion class :Ex ia IIC T4 Ga Others: CE Marking |
Standard Features |
2 Smart sensors slots auto recognize sensor changes
Library of over 600 VOC’s for 10.6 eV lamp, 300 VOC’s for 10.0 eV lamp
User defined VOC list. Up to 30 frequently used
Recent VOC list for last 8 selected gases
Pump and circuit status indicators
User & station ID selection menu
Datalogging (interval, alarm trend, station and user ID)
Snap logging - on demand data logging
Demand zero / Auto zero
BUMP and CAL expiration alarm
Flashlight
IrDA communication |
Standard Accessories |
Rubber boot
Belt clip
Hand strap
Tapper nozzle
Probe with hydrophobic & dust filter 3' teflon lined hose |
Optional Accessories |
SDM-6000 calibration station
Bundles with instrument carrying case and accessories
Flexible probes
Up to 40 foot sample hoses
Filter set
IrDA cable |
Warranty |
Two years material (including sensors) and workmanship. One year for PID sensor |