Inplant Handler, Cell Size 2-1/2 x 7-1/4 x 3/4"
Transportation of sensitive products outside of an EPA shall require packaging that provides:
1. Low charge generation.
2. Dissipative or conductive materials for intimate contact.
3. A structure that provides electrostatic discharge shielding.
(ANSI/ESD S541 section 6.2 Outside an EPA)
"Packaging materials that are in intimate contact with devices should be dissipative."
ANSI/ESD S541 section 7.2.2 Resistance of Dissipative Materials
ESD Handbook TR 20.20 paragraph 5.4.3.3.1 Returnable and Reusable Packaging, “In some situations, packaging may be designed for reuse [and] may be reused numerous times. Examples of these types of ESD protective packaging are hinged containers, boxes, and other rigid or semi-rigid containers. The initial cost of these packages may be relatively expensive. However, if the appropriate collection and recycling system is used, the container may be the least expensive choice over time.”
ESD protective packaging shall be marked with the ESD Protective Symbol." "Packaging should be marked with information that allows traceability to the packaging manufacturer and the manufacturer's date/lot code information. The date/lot code should allow traceability to quality control information of the manufacture of the specific lot of packaging." (ANSI/ESD S541 section 8.2.1 Material Identification and section 8.2.3 Traceability).