Input voltage |
Maximum voltage: 264 V AC
Normal voltage: 100~240 V AC
Minimum voltage: 90 V AC |
Input frequency |
Maximum frequency: 63 Hz
Normal frequency: 50 to 60 Hz
Minimum frequency: 47 Hz |
Input current |
1.5 A max. at 115 V AC input with full load
0.75 A max. at 230 V AC input with full load |
Energy-saving standard |
Average efficiency ≥ 89% under normal line input
No-load power consumption: ≤ 0.15 W at normal line input
10% load efficiency ≥ 79% under normal line input |
Configuration |
3-wire AC input (line, neutral, FG) |
Line regulation |
Less than ± 1%, of rated output voltage at full load |
Harmonic standard and power factor |
Complies with IEC 61000-3-2 Class D harmonic standard with input power over 75 W.
Power factor > 0.95 at 100 V AC input and >0.9 at 240 V AC input at full load |
Output voltage and current |
Output voltage: 12 V
Current min: 0 A
Current max: 7 A |
Load regulation at 12 V |
Output voltage range: 11.4 V to 12.6 V |
Ripple and noise |
For 12 V output, ripple and noise will not exceed 240 mV (pk-pk) |
Overvoltage protection |
150% of the rated output voltage |
Stability |
2% maximum at constant load with constant input (after 30 minutes of operation) |
Temperature |
Operating : 0 °C to 40 °C
Storage : –20 °C to 85 °C |
Humidity |
Operating : 10 to 90 %
Storage: 5 to 90 % |
Max. altitude |
2000 m |
Leakage current |
250 µA, at 240 V AC (50 Hz) |
Safety |
UL/CUL, TUV, CB, CE, FCC, EK, PSE, RCM, CU, BSMI, CCC |
EMI |
CISPR 32, EN 55032 Class B
FCC PART 15 Class B |
Physical size |
137 mm x 59 mm x 34 mm |
Net weight |
450 g |