General Specifications |
Model |
VMS-1 |
VMS-2 |
VMS-3 |
Input |
110-120 VAC, 10 A, 1-phase
50/60 Hz |
220-240 VAC, 25 A, 1-phase
50/60 Hz |
120 or 240 VAC, 10 A, 1-phase
50/60 Hz |
Output |
AC |
≈ 0-120 VAC, 10 AAC max |
≈ 0-220/240 VAC*, 25 AAC max |
≈ 0-120 VAC*, 10 AAC max |
DC |
n/a |
≈ 0-300 VDC, 10 ADC max |
≈ 0-150 VDC, 5 ADC max |
|
*Maximum AC output voltage depends on input voltage of the test set |
Duty Cycle |
|
continuous |
|
Cables Included |
Input/Output |
6' (1.8 m)/10' (3 m) |
10' (3 m)/10' (3 m) |
10' (3 m)/10' (3 m) |
Dimensions & Weight |
Length/Width & Height/Weight |
20" (508 mm) /16" (406 mm) & 8" (203 mm)/29 lbs (13 kgs) |
24" (610 mm) /22" (559 mm) & 24" (610 mm) /105 lbs (48 kgs) |
20" (508 mm) /16" (406 mm) & 8" (203 mm)/29 lbs (13 kgs) |
Model |
VMS-4 |
VMS-5 |
VMS-8 |
Input |
220-240 VAC, 25 A, 1-phase
50/60 Hz |
120 or 240 VAC, 50 A, 1-phase
50/60 Hz |
120 VAC, 30 A or 240 VAC, 15A, 1-phase
50/60 Hz |
Output |
AC |
n/a |
≈ 0-240 VAC*, 50 AAC max |
≈ 0-240 VAC*, 10 AAC max |
DC |
≈ 0-100 VDC, 40 ADC max |
≈ 0-100 VDC, 100 ADC max |
≈ 0-300 VDC, 10 ADC max |
|
*Maximum AC output voltage depends on input voltage of the test set |
Duty Cycle |
continuous |
|
|
Cables Included |
Input/Output |
10' (3 m)/10' (3 m) |
10' (3 m)/10' (3 m) |
10' (3 m)/10' (3 m) |
Dimensions & Weight |
Length/Width & Height/Weight |
24" (610 mm) /22" (559 mm) & 24" (610 mm) /144 lbs (65 kgs) |
24" (610 mm) /22" (559 mm) & 24" (610 mm) /185 lbs (84 kgs) |
20" (508 mm) /16" (406 mm) & 8" (203 mm)/164 lbs (74 kgs) |
Metering |
3 1/2 digit, LED display |
AC Voltmeter
Accuracy ±0.4% Full Scale ±2 counts |
AC Currentmeter
Accuracy ±0.15% Full Scale ±6 counts |
DC Voltmeter
Accuracy ±0.1% Full Scale ±1 count |
DC Currentmeter
Accuracy ±0.1% Full Scale ±1 count |