Model: IR 3100 Specifications |
Power Requirements |
120 VAC, 50/60 Hz (1550 Watts maximum).
Requires dedicated 15 A supply |
Dimensions |
737mm (29") H x 686mm (27") W x 737mm (29") D |
Weight (Without Computer) |
45kg (100lbs) |
Top-side Heater |
Medium/Long wave IR, 500 Watts |
Bottom-side Preheater with Adjustable Working Height |
Medium/Long wave IR, 1000 Watts; 220mm (8.6") x 155mm (6.1"); Adjustable working height from lowest position up to 38mm (1.5") closer to the PCB |
High Sensitivity Vacuum Pick |
Pick is counterweight balanced, and utilizes an optical sensor and precision high temperature linear ball bearings, ensuring delicate placement and pick up of parts from PCB. Includes seven (6) Vacuum Picks |
Precision Placement Capability |
Advanced professional placement system utilizing a stepper motor and position encoding provides smooth, precise movement, with no drift, allowing for repeatable and accurate placement. |
Placement Accuracy |
Stepper motor with precision positioning of to 28µm (.0011") accuracy |
Board Support Capability |
Integrated Board Support Wand prevents PCBs from sagging/warping during rework and is adjustable to clear parts on bottom of PCB |
Maximum Target Temperature |
Each profile zone has a maximum target temperature of 328°C (624°F) |
Precision PCB Holder |
Advanced table features micrometer X & Y adjustment, extruded board holder arms, spring loaded, with T-slots and movable clamps for both large and irregularly shaped boards with non-uniform edges |
Maximum/Minimum PCB Size |
Maximum: 305mm x 305mm (12" x 12"); Minimum: N/A arms close down completely. |
Maximum/Minimum Component Size |
Maximum: 65mm (2.5") x 65mm (2.5"); Minimum: 1mm Sq. |