Toll Free: (877) 571-7901
Local: (732) 728-2590
salesteam@tequipment.net
My Account
Sign in to see your member price, rewards, orders, tracking and more.
Why Join? Gain access to exclusive pricing, rewards and more!
Member Pricing & Rewards active
(877) 571-7901
Sales@TEquipment.NET
Member Pricing & Rewards are active.
Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Catalog: 35411-01 | UPC: 643765529470 | Model: Oakton WD-35411-01
Oakton CON 700 Meter with Probe, Stand, and NIST-Traceable Calibration
List Price: $1,025.00
Your Price: $854.17
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
CON 700 meter reads 0 to 199.9 mS across five ranges-autoranging feature automatically gives the best resolution for your measurements. Calibrate at up to five conductivity points (one per range) for improved measurement accuracy. Adjustable temperature coefficient provides additional accuracy. Cell constant is selectable for very high or low range measurements - meter is flexible to your application. Selectable manual or automatic temperature compensation gives greater precision. Meter is encased in a compact 6-1/8" L x 6-7/8" W x 2-3/4" housing which takes up a minimum of bench space. Water-resistant membrane keypad and convenient pullout reference guide provide useful features for the lab. Large dual display shows conductivity or TDS and temperature and has a “ready” indicator and HOLD function.
The CON700 includes an electrode with a nominal cell constant of k = 1.0, built-in temperature sensor, and 1 meter cable. The Ultem body housing has good chemical resistant properties. The electrode design offers fast temperature response and reduces air entrapment, ensuring accurate, repeatable, and stable readings. The wetted materials of the probe include:
The protective probe guard can be removed temporarily for cleaning however it must be re-attached during measurement and calibration. Erroneous results will occur while the probe guard is removed. Always immerse the probe beyond upper steel band for best results. Use the fill line on the outside of the probe guard for reference.
Automatic or Manual Calibration The CON 700 is capable of automatic or manual calibration for conductivity, and manual calibration for TDS. In the automatic calibration mode, the meter will automatically select one of (4) conductivity calibration standard values depending on the range and normalization temperature being used (TABLE 1). If you only use calibration standards that are listed in TABLE 1, automatic calibration is recommended. If you intend to calibrate with one or more standards that are not listed in TABLE 1, the CON 700 must be set for manual calibration instead. The factory default is automatic conductivity calibration. See Section 6.10 to change this setting. There is no automatic calibration value available for conductivity range 1.
Single or Multi-Point Calibration Use Single-Point Calibration to apply a single calibration value across all ranges. Use Multi-Point Calibration for individual calibration in each range. This will restrict an individual calibration so that it is applied to one range only. When using multi-point calibration, perform a calibration in each range that you expect to use for best results. The factory default is Single-Point Calibration. See Section 6.11 to change this setting. General Calibration Tips For best results, periodic calibration with known accurate standards is recommended. A maximum of one calibration point per range can be performed. If multiple calibration points are used in the same range, the most recent one will replace the previous one. When the electrode is replaced, it is best to clear the calibration to the factory default values. Rinse or immerse the probe before calibration and between samples with clean water (deionized water is ideal). The CON 700 has non-volatile memory which will retain all calibration values, as well as meter settings and memory values upon meter shut down or unexpected power loss. To protect from erroneous calibrations, the allowable tolerance is ±40% of the factory default value. Low conductivity standard solutions (less than 20 µS) are unstable and are very temperature dependent. As a result, reproducible calibration results are challenging in lowest measurement range #1 (0.00 to 20.0 µS).
Automatic Conductivity Calibration Procedure
Manual Conductivity & TDS Calibration Procedure
Temperature Calibration The thermistor sensor used for automatic temperature compensation and measurement is accurate and stable, so frequent calibration isn’t required. Temperature calibration is recommended upon probe replacement, whenever the temperature reading is suspect, or if matching against a certified thermometer is desired.