Model ZDP200I-10KIT Specifications |
Approvals: |
CSA certification for intrinsic safety use in Class 1, Groups A, B, C and D areas. CE and CENELEC approvals. (Both Optional) |
Display: |
8 digit (4 pressure or DP and 4 voltage or current) LCD type with .3" high (7.6 mm) digits. |
NIST traceability: |
NIST certificate supplied for all models. |
Power: |
NI-CAD Rechargeable, Minimum of 40 Hrs @ 70˚F (21˚C); 20 Hrs @ -20˚F (-29˚C) |
Temperature: |
Storage: -40˚F to 140˚F (-40˚C to 60˚C)
Operating: -20˚F to 122˚F (-6.7˚C to 50˚C)
Effect: None within the calibrated range of -4˚ to 104˚F |
Process connection: |
1/8" OD Presto-lok |
Enclosure: |
1.1 pounds (0.5 kg) 4 x 7.5 x 1.9 (102mm x 191mm x 48mm). Impact resistant ABS material. |
Pressure limits: |
Twice range on Gauge (LP) units. Twice range on Differential (DP) units when pressurized on high side only and 150 PSI (10.5 Kg/cm2 ) static when applied to both sides of the sensor simultaneously. |
Media compatibility: |
Non-isolated sensor for clean, dry, non-corrosive gases. |
Auto Zero: |
A push of a button automatically establishes zero. There is no need to compute compensation factors for local gravity, temperature, or head difference due to the location of the tester vs. the unit under test. |
Engineering units: |
in H2O at 20˚C, cm H2O, PSI, in Hg at 0˚C, mm Hg, Kg/cm2, kPa, mBar and user scaled. |
Resolution: |
Auto-ranging for optimal accuracy and resolution of the display for both pressure and electrical inputs. |
Electrical Measurement: |
Voltage: 0 to 30 Vdc
Current: 0 to 30 mAdc |
Accuracy: |