Output Ratings |
Rated Output Voltage (*1) |
60V |
Rated Output Current (*2) |
25A |
Rated Output Power |
1500W |
Ripple and Noise (*5) |
CVp-p (10 - 20MHz) p-p (*6) |
60mV |
CVrms (5Hz - 1MHz) r.m.s. (*7) |
8mV |
CCrms (5Hz - 1MHz) r.m.s. (*12) |
75mV |
Load Regulation |
Voltage (*3) |
8mV |
Current (*3) |
10mA |
Line Regulation |
Voltage (*3) |
8mV |
Current (*3) |
4.5mA |
Analog Programming and Monitoring |
External Voltage Control Output Voltage |
Accuracy and Linearity: +/- 0.5% of Rated Output Voltage |
External Voltage Control Output Current |
Accuracy and Linearity: +/- 1% of Rated Output Voltage |
External Resistor Control Output Voltage |
Accuracy and Linearity: +/- 1% of Rated Output Voltage |
External Resistor Control Output Current |
Accuracy and Linearity: +/- 1.5% of Rated Output Voltage |
Output Voltage Monitor |
Accuracy: +/- 1% |
Output Current Monitor |
Accuracy: +/- 1% |
Shutdown Control |
Turns The Output off With a LOW (0V to 0.5V) or Short-Circuit |
Output On/Off Control |
Possible Logic Selections: |
Turn the output on using a LOW (0 V to 0.5 V) or short-circuit |
Turn the output off using a HIGH (4.5 V to 5 V) or open-circuit |
Turn the output on using a HIGH (4.5 V to 5 V) or open-circuit |
Turn the output off using a LOW (0 V to 0.5 V) or short-circuit |
Alarm Clear Control |
Clear alarms with a LOW (0 V to 0.5 V) or short-circuit |
CV / CC / ALM / PWRON / OUT ON Indicator |
Photocoupler open collector output; Maximum voltage 30 V, maximum sink current 8 mA |
Trigger Out |
Maximum low level output = 0.8 V |
Minimum high level output = 2 V |
Maximum source current = 8 mA |
Trigger In |
Maximum low level input voltage = 0.8 V |
Minimum high level input voltage = 2 V |
Maximum sink current = 8 mA |
Transient Response Time |
1ms |
OUTPUT RESPONSE TIME |
Rise Time (*8) |
Rated Load |
80ms |
No Load |
80ms |
Fall Time (*9) |
Rated Load |
10ms |
No Load |
11000ms |
Programming and Measurements (RS-232/485, USB LAN) |
Output Voltage Programming Accuracy 0.05%+ |
30mV |
Output Current Programming Accuracy 0.2%+ |
25mA |
Output Voltage Programming Resolution |
2mV |
Output Current Programming Resolution |
0.8mA |
Output Voltage Measurement Accuracy 0.1%+ |
60mV |
Output Current Measurement Accuracy 0.2%+ |
50mA |
Output Voltage Measurement Resolution |
2mV |
Output Current Measurement Resolution |
0.8mA |
Protection Function |
Over Voltage Protection (OVP) |
Setting Range |
5V - 66V |
Setting Accuracy |
600mV |
Over Current Protection (OCP) |
Setting Range |
2.5A - 27.5A |
Setting Accuracy |
500mA |
Over Voltage Limit (UVL) Setting Range |
0V - 63V |
Over Temperature Protection (OHP) Operation |
Turn the output off |
Incorrect Sensing Connection Protection (SENSE) Operation |
Turn the output off |
Low AC Input Protection (AC-FAIL) Operation |
Turn the output off |
Shutdown (SD) Operation |
Turn the output off |
Power Limit (POWER LIMIT) Operation |
Overpower limit |
Power Limit Value (Fixed) |
105% of rated output power |
Input Characteristics |
Nominal Input Rating |
100Vac to 240Vac, 50 - 60Hz, Single Phase |
Input Voltage Range |
85Vac - 265Vac |
Input Frequency Range |
47Hz - 63Hz |
Maximum Input Current (100Vac / 200Vac) (A) |
21 / 11 |
Inrush Current |
Less than 50A |
Maximum Input Power |
200VA |
Power Factor (100Vac / 200Vac) |
0.99 / 0.98 |
Hold-up Time |
20ms or greater |
Efficiency (100Vac / 200Vac) (%) |
84 / 87 |
Dimensions (w x H x D) |
423mm x 43.6mm x 447.2mm |
Weight |
8.7kg |
(*1) Minimum voltage is guaranteed to maximum 0.2 % of the rated output voltage.
(*2) Minimum current is guaranteed to maximum 0.4 % of the rated output current.
(*3) At 85 -132 Vac or 170 - 265 Vac, constant load.
(*4) From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
(*5) Measure with JEITA RC-9131B (1:1) probe.
(*6) Measurement frequency bandwidth is 10 Hz - 20 MHz.
(*7) Measurement frequency bandwidth is 5 Hz - 1 MHz.
(*8) From 10 % - 90 % of rated output voltage, with rated resistive load.
(*9) From 90 % -10 % of rated output voltage, with rated resistive load.
(*10) Time for output voltage to recover within 0.5 % of its rated output for a load change from 10 - 90 % of its rated output current. Voltage set point from 10 % -100 % of rated output.
(*11) For load voltage change, equal to the unit voltage rating, constant input voltage.
(*12) For 6 V model the ripple is measured at 2 - 6 V output voltage and full output current. For other models, the ripple is measured at 10 - 100 % output voltage and full output current.
(*13) At rated output power.
(*14) If the front panel filter kit is installed, the temperature is guaranteed to 40 °C. |