Vertical |
Bandwidth |
40 kHz |
Input Channels |
8 (SAM40-8), 16 (SAM40-16), 24 (SAM40-24) |
Vertical Resolution |
24 bits, stored and displayed as 32-bit floating point waveforms |
Effective Number of Bits (ENOB) |
13 (40 kHz bandwidth), 15 (2 kHz bandwidth) |
Vertical Noise Floor |
31 μVrms at 1-2 mV/div, 35 μVrms at 5-100 mV/div, 56 μVrms at 200 mV/div, 355 μVrms at 500 mV/div and 1 V/div |
Sensitivity |
1 mV to 10 V/div in 1, 2, 5 steps |
DC Vertical Gain Accuracy |
±(0.02% of reading + 0.02% F.S. + 100μV) at 23°C ± 5°C. Add ±(0.0015% F.S. + 10μV)/°C outside of stated temperature range |
Maximum Input Voltage |
±50 Vpeak for DC, AC, and GND coupling. ±24 Vpeak for IEPE coupling (use IEPE coupling with appropriate sensor). |
Input Coupling |
AC 1MΩ, DC 1MΩ, IEPE, GND. AC coupling frequency 0.16 Hz ±10% |
Input Impedance |
1 MΩ ±0.5% // 55 pF |
Bandwidth Limiters |
100 Hz, 500 Hz, 2 kHz, 10 kHz. Implemented as digital IIR filters in FPGA |
Rescaling |
Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2 g0; Volume: liters, m3, in3, ft3, yd3; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/ second, revolution/minute, N·m, lb-ft, lb-in, oz-in, watt, horsepower; Other: % |
Horizontal and Acquisition |
Acquisition Modes |
Real-time (coincident with and as controlled by a compatible oscilloscope) |
Sample Rate |
(single-shot) 1 S/s to 100 kS/s on all channels |
Memory |
Length 2.5 Mpt/ch on each acquisition channel |
Triggering System |
Modes |
Normal, Auto, Single, and Stop when cross-triggered by a supported oscilloscope |
Probes |
Probe System |
BNC Input, IEPE/ICP Compatible. Excitation Output Current = 4mA ±15% (23°C ± 5°C, +0.5%/°C outside of range). Compliance Voltage = 24V |
Scale Factors |
Manually selected in supported oscilloscope |
Power Requirements |
Voltage |
100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection |
Max. Power Consumption |
50 W / 50 VA |
Environmental |
Temperature |
0 °C to +50 °C (operating); –40 °C to +70 °C (non-operating) |
Humidity |
5% to 90% relative humidity (non-condensing) up to +30 °C. Upper limit derates to 50% relative humidity (noncondensing) at +50 °C. (operating).
5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F (non-operating) |
Altitude |
Up to 10,000 ft. (3048 m) at or below +25 °C (operating). Up to 40,000 ft. (12,192 m) (non-operating) |
Size and Weight |
Dimensions |
3.97"H x 16.79"W x 13.38"D (101 mm x 426 mm x 340 mm) |
Weight |
9.56 lbs. (4.35 kg) |
Certifications |
CE Certification |
CE Compliant |