LeCroy HVD3206 2kV, 120 MHz High Voltage Differential Probe
- 120 MHz High Voltage Differential Probe
- 2 kV CAT safety rated
- 1% gain accuracy
- High offset capability at both high and low attenuation
- AC or DC coupling
- Auto-zero capabilities
- Wide oscilloscope compatibility
High Voltage Differential Probe
The
HVD3206 is specifically designed for 1500 Vdc solar photovoltaic (PV) measurements per the IEC/EN 61010-031:2015 standard.
The HVD3000 series high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
Worlds Only 2 Safety Rated Model
The HVD3206 probe is rated to 1500 Vdc (2000 V DC + peak AC). This makes the probe ideal for testing single-phase or three-phase inverters or newer 1500 Vdc rated string-inverters (per IEC/EN 61010-031:2015). The HVD3206 has the same excellent 1% gain accuracy, industry-leading CMRR, industry-best offset range, and a guaranteed 2000 Vpk differential voltage range.
- Only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015 (certification pending)
- Guaranteed 2000 Vpk differential voltage range
- Industry’s best offset capability (1500 V) when used with HDO Series oscilloscopes
- Bandwidth rating of 120 MHz
Exceptional Common-Mode Rejection Ratio
The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability makes the probes capable of measuring very small control signals floating on high common-mode voltages.
High Precision Measurements
HVD probes provide 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement.
Complete Probe Integration
The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.
Teledyne LeCroy high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments.The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
The HVD3000 series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV class electricalapparatus. The table below provides a list of recommended probe models based on specific device under test applications.
Device Under Test |
Recommended Model |
Safety Class |
Bandwidth |
Cable Length |
Tip Accessories Included |
120 V/240 V Half-Bridge Circuit Topologies |
HVD3102 |
1 kV |
25 MHz |
2 m |
Yes |
HVD3102-NOACC |
1 kV |
25 MHz |
2 m |
No |
HVD3106 |
1 kV |
120 MHz |
2 m |
Yes |
HVD3106-NOACC |
1 kV |
120 MHz |
2 m |
No |
380 V - 600 V Class Electrical Apparatus |
HVD3106 |
1 kV |
120 MHz |
2 m |
Yes |
HVD3106-NOACC |
1 kV |
120 MHz |
2 m |
No |
HVD3106-6M |
1 kV |
80 MHz |
6 m |
Yes |
Solar PV Inverter |
HVD3106 |
1 kV |
120 MHz |
2 m |
Yes |
HVD3206 |
2 kV |
120 MHz |
2 m |
Yes |
5 kV Electrical Apparatus |
HVD3605 |
8.485 kV |
100 MHz |
6 m |
Yes |