DC Power Module (35V/1.5A/50W)
The Keysight N6730 Series of DC power modules provides programmable voltage and current, measurement, and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources, such as fixture control.
| DC output ratings (volts/amps/watts) | Ripple & noise (p-p/rms) | Voltage programming accuracy | Current programming accuracy | Voltage measurement accuracy | Current measurement accuracy |
N6731B | 5 V/10 A/50 W | 10 mV/2 mV | 0.1% + 19 mV | 0.15% + 20 mA | 0.1% + 20 mV | 0.15% + 20 mA |
N6732B | 8 V/6.25 A/50 W | 12 mV/2 mV | 0.1% + 19 mV | 0.15% + 20 mA | 0.1% + 20 mV | 0.15% + 10 mA |
N6733B | 20 V/2.5 A/50 W | 14 mV/3 mV | 0.1% + 20 mV | 0.15% + 20 mA | 0.1% + 20 mV | 0.15% + 5 mA |
N6734B | 35 V/1.5 A/52.5 W | 15 mV/5 mV | 0.1% + 35 mV | 0.15% + 20 mA | 0.1% + 35 mV | 0.15% + 4 mA |
N6735B | 60 V/0.8 A/50 W | 25 mV/9 mV | 0.1% + 60 mV | 0.15% + 20 mA | 0.1% + 60 mV | 0.15% + 4 mA |
N6736B | 100 V/0.5 A/50 W | 30 mV/18 mV | 0.1% + 100 mV | 0.15% + 10 mA | 0.1% + 100 mV | 0.15% + 2 mA |
Options 054, 760 and 761
Option 054 (High-speed Test Extensions) includes an output list and digitized measurement capability. This option is separately orderable for Models N673xB, N674xB, N677xA, and N675xA when installed in N6700 MPS mainframes. All other power modules as well as the N6705 DC Power Analyzer mainframes, have an output list and digitized measurement capability built in.
- Output list:
- Maximum number of steps = 512
- Maximum dwell time in seconds = 262
- Maximum list repetitions = 256 or infinite
- Digitized measurement:
- Maximum measurement points = 524,288
- Maximum sample rate = 97.656 kHz
With option 760, Output Disconnect/Polarity Reversal Relays, mechanical relays switch the leads on both the plus and the minus side of the power supply, including the sense leads, resulting in a voltage polarity reversal at the DUT. In addition to polarity reversal, option 760 provides the same output disconnect function as option 761.
With option 761, Output Disconnect Relays, an emergency condition or turning the DC output off causes mechanical relays to disconnect both the plus and minus sides of the power supply, including the sense leads.
Many models available
Keysight offers a variety of modules for use with its N6700 product family, including power supplies, loads, and SMUs. Each of the series names below is clickable and will open a link in a new window to that particular group.
- N6730 - Basic DC power modules (50W)
- N6740 - Basic DC power modules (100W)
- N6750 - High performance DC power modules (up to 500W)
- N6760 - Precision DC power modules (up to 500W)
- N6770 - Basic DC power modules (300W)
- N6780 - Source measure unit (SMU) modules
- N6790 - Load modules