Source |
Measure3 |
Range4 |
Resolution |
Accuracy5
23°C ± 5°C, 1 Year ±(% setting + volts) |
Noise (RMS)
<10 Hz |
Resolution |
Input Resistance |
Accuracy
23°C ± 5°C, 1 Year ±(% reading + volts) |
200.0000 mV |
5 µV |
0.015% + 200 µV |
2 µV |
100 nV |
> 10 GΩ |
0.012% + 200 µV |
2.000000 V |
50 µV |
0.020% + 300 µV |
10 µV |
1 µV |
> 10 GΩ |
0.012% + 300 µV |
20.00000 V |
500 µV |
0.015% + 2.4 mV |
100 µV |
10 µV |
> 10 GΩ |
0.015% + 1 mV |
200.0000 V |
5 mV |
0.015% + 24 mV |
1 mV |
100 µV |
> 10 GΩ |
0.015% + 10 mV |
1000.000 V |
50 mV |
0.02% + 100 mV |
20 mV |
10 mV |
> 10 GΩ |
0.015% + 50 mV |
Temperature Coefficient |
± (0.15 × accuracy specification)/°C, 0°C to 18°C and 28°C to 50°C |
|
Source |
Measure3 |
Range4 |
Resolution |
Accuracy5
23°C ± 5°C, 1 Year ±(% setting + amps) |
Noise (RMS)
<10 Hz |
Resolution |
Voltage Burden |
Accuracy
23°C ± 5°C, 1 Year ±(% reading + amps) |
10.00000 nA6 |
500 fA |
0.100% + 200 pA |
500 fA |
10 fA |
< 100 µV |
0.10% + 250 pA |
100.0000 nA6 |
5 pA |
0.060% + 250 pA |
500 fA |
100 fA |
< 100 µV |
0.060% + 300 pA |
1.000000 μA |
50 pA |
0.025% + 400 pA |
5 pA |
1 pA |
< 100 µV |
0.025% + 300 pA |
10.00000 μA |
500 pA |
0.025% + 1.5 nA |
40 pA |
10 pA |
< 100 µV |
0.025% + 700 pA |
100.0000 μA |
5 nA |
0.020% + 15 nA |
400 pA |
100 pA |
< 100 µV |
0.02% + 6 nA |
1.000000 mA |
50 nA |
0.020% + 150 nA |
5 nA |
1 nA |
< 100 µV |
0.02% + 60 nA |
10.00000 mA |
500 nA |
0.020% + 1.5 μA |
40 nA |
10 nA |
< 100 µV |
0.02% + 600 nA |
100.0000 mA |
5 μA |
0.025% + 15 μA |
100 nA |
100 nA |
< 100 µV |
0.025% + 6 μA |
1.000000 A |
50 μA |
0.067% + 900 μA |
10 μA |
1 μA |
< 100 µV |
0.03% + 500 μA |
Temperature Coefficient |
± (0.15 × accuracy specification)/°C, 0 °C to 18 °C and 28 °C to 50 °C |
Notes
1. Speed = 1 PLC.
2. All specifications are guaranteed with output ON.
3. Accuracies apply to 2-wire and 4-wire modes when properly zeroed. For the 200 mV and 1 A ranges, the voltage burden may exceed the specification in 2-wire mode.
4. Maximum display and programmming ranges are 5% overrange for voltage, except for the 1000 V range, which is 10% overrange (1100 V), and 5% overrange for current (for example,
1.05 A on the 1 A range).
5. For sink mode, accuracy is ±(0.15% + offset × 4) except for 1 A range, accuracy is: ± (1.5% + offset × 8).
6. Rear-panel triaxial connections only |
Range |
Default Resolution10 |
Default Test Current |
Normal Accuracy
23°C ± 5°C, 1 Year ± (% reading + ohms) |
Enhanced Accuracy11
23°C ± 5°C, 1 Year ± (% reading + ohms) |
< 2.000000 Ω12 |
1 µΩ |
User-defined |
Source IACC + Meas VACC |
Meas IACC + Meas VACC |
20.00000 Ω |
10 µΩ |
100 mA |
0.098% + 0.003 Ω |
0.073% + 0.001 Ω |
200.0000 Ω |
100 µΩ |
10 mA |
0.077% + 0.03 Ω |
0.053% + 0.01 Ω |
2.000000 kΩ |
1 mΩ |
1 mA |
0.066% + 0.3 Ω |
0.045% + 0.1 Ω |
20.00000 kΩ |
10 mΩ |
100 µA |
0.063% + 3 Ω |
0.043% + 1 Ω |
200.0000 kΩ |
100 mΩ |
10 µA |
0.065% + 30 Ω |
0.046% + 10 Ω |
2.000000 MΩ |
1 Ω |
1 µA |
0.11% + 300 Ω |
0.049% + 100 Ω |
20.00000 MΩ |
10 Ω |
1 µA |
0.11% + 1 kΩ |
0.052% + 500 Ω |
200.0000 MΩ13 |
100 Ω |
100 nA |
0.655% + 10 kΩ |
0.349% + 5 kΩ |
> 200.0000 MΩ12, 13 |
- |
User-defined |
Source IACC + Meas VACC |
Meas IACC + Meas VACC |
Temperature Coefficient |
± (0.15 × accuracy specification)/°C 0 °C to 18 °C and 28 °C to 50 °C |
Source Current, Measure Resistance Mode |
Total uncertainty = I source accuracy + V measure accuracy (4-wire remote sense) |
Source Voltage, Measure Resistance Mode |
Total uncertainty = V source accuracy + I measure accuracy (4-wire remote sense) |
Guard Output Impedance |
≥ 300 Ω typical |
Notes
7. Speed = 1 PLC.
8. All specifications are guaranteed with output ON.
9. Accuracies apply to 2-wire and 4-wire modes when properly zeroed.
10. Measure resolution 6.5 digits.
11. Source readback enabled; offset compensation on.
12. Source current, measure resistance or source voltage, measure resistance only.
13. Rear-panel triaxial connections only |
Overrange |
105% of range for 200 mV to 200 V, source and measure ranges; 110% of range for 1000 V, source and measure ranges |
Regulation |
Voltage |
Line: 0.01% of range
Load: 0.01% of range + 100 µV |
Current |
Line: 0.01% of range
Load: 0.01% of range + 100 pA |
Source Limits |
|
Voltage Source Current Limit |
Bipolar current limit set with a single value
Minimum value is 10% of range |
Current Source Voltage Limit |
Bipolar voltage limit set with a single value
Minimum value is 10% of range |
Voltage Limit/Current Limit Accuracy |
Add 0.3% of range and ±0.02% of reading to base specification |
Overshoot |
Voltage Source |
< 0.1% typical
Step size = Full scale, resistive load, 20 V range, 10 mA current limit |
Current Source |
< 0.1% typical
Step size = Full scale, resistive load of 10 kΩ, 1 mA range, 20 V voltage limit |
Range Change Overshoot |
Overshoot into a fully resistive 100 kΩ load, 10 Hz to 20 MHz bandwidth, adjacent ranges: 250 mV typical |
Output Settling Time |
Time required to reach 0.1% of final value after command is processed and output slew: 20 V range, 100 mA current limit: < 200 µs typical |
Maximum Slew Rate 14 |
0.2 V/µs, 200 V range, 100 mA limit into a 2 kΩ load (typical)
0.5 V/µs, 1000 V range, 10 mA limit into a 100 kΩ load (typical) |
Overvoltage Protection |
User-selectable values, 10% tolerance; factory default = none |
Voltage Source Noise |
10 Hz to 20 MHz (RMS): 4 mV typical into a resistive load |
Common Mode Voltage |
250 V DC |
Common Mode Isolation |
> 1 GΩ, < 1000 pF |
Notes
14. High capacitance mode off. |
NPLC |
NMRR |
CMRR |
0.01 |
- |
60 dB |
0.1 |
- |
60 dB |
1 |
60 dB |
100 dB* |
* Except 10 nA and 100 nA current ranges ~90 dB |
Normal Mode |
20 nF typical |
High-Capacitance Mode |
Stable into 1 μF typical (specification only valid for ranges ≥100 μA) |
Maximum Voltage Drop Between Force and Sense Terminals |
5 V |
Maximum Sense Lead Resistance |
1 MΩ for rated accuracy |
Sense Input Impedance |
> 10 GΩ |
Guard Offset Voltage |
< 300 µV typical |
Reading rates (readings per second) typical for 60 Hz (50 Hz), script (TSP) programmed |
NPLC |
Trigger Origin |
Measure to Memory |
Measure to GPIB |
Measure to USB |
Measure to LAN |
Source Measure Sweep to Memory |
Source measure sweep to GPIB |
Source Measure Sweep to USB |
Source Measure Sweep to LAN |
0.01 |
Internal |
3150 (2800) |
2760 (2570) |
2825 (2570) |
2740 (2530) |
1710 (1620) |
1620 (1540) |
1630 (1540) |
1620 (1540) |
0.01 |
External |
2170 (2050) |
2120 (2003) |
2170 (2010) |
2100 (1990) |
1670 (1590) |
1580 (1500) |
1590 (1510) |
1580 (1510) |
0.10 I |
Internal |
540 (460) |
530 (450) |
530 (450) |
530 (450) |
470 (410) |
460 (400) |
470 (400) |
470 (400) |
0.10 |
Externa |
500 (430) |
490 (420) |
500 (425) |
480 (420) |
450 (400) |
460 (390) |
460 (390) |
410 (350) |
1.00 |
Internal |
59 (49) |
58 (49) |
59 (49) |
59 (49) |
58 (48) |
58 (48) |
58 (48) |
57 (48) |
1.00 |
External |
58 (48) |
57 (48) |
58 (48) |
58 (48) |
57 (48) |
57 (48) |
57 (48) |
55 (48) |
Reading rates (readings per second) typical for 60 Hz (50 Hz), SCPI programmed 16 |
NPLC |
Trigger Origin |
Measure to Memory |
Measure to GPIB |
Measure to USB |
Measure to LAN |
Source Measure Sweep to Memory |
Source measure sweep to GPIB |
Source Measure Sweep to USB |
Source Measure Sweep to LAN |
0.01 |
Internal |
3040 (2800) |
3000 (2760) |
3000 (2760) |
3010 (2710) |
1710 (1630) |
1610 (1544) |
1440 (1380) |
1690 (1590) |
0.01 |
External |
2320 (2165 |
2290 (2140) |
2340 (2150) |
2290 (2130) |
1680 (1590) |
1560 (1525) |
1410 (1360) |
1660 (1560) |
0.10 |
Internal |
540 (460) |
540 (450) |
540 (460) |
540 (450) |
470 (410) |
470 (410) |
450 (390) |
470 (410) |
0.10 |
External |
510 (440) |
510 (430) |
510 (440) |
510 (430) |
470 (400) |
470 (400) |
450 (390) |
470 (400) |
1.00 |
Internal |
59 (49) |
59 (49) |
59 (49) |
59 (49) |
58 (48) |
58 (48) |
57 (48) |
58 (48) |
1.00 |
Externa |
58 (49) |
58 (49) |
58 (49) |
58 (49) |
58 (48) |
58 (48) |
57 (47) |
58 (48) |
Notes
15. Reading rates applicable for voltage or current measurements, autozero off, autorange off, filter off, binary reading format, and source readback off.
16. SCPI programming mode. |
Factory Default Standard Power-Up Setting |
SCPI mode |
Source Output Modes |
Fixed DC level
Memory/configuration list (mixed function)
Stair (linear and logarithmic) |
Memory Buffer |
>5,000,000 readings with selected measured values and timestamp |
Real-Time Clock |
Lithium battery backup (more than 3 years of battery life) |
Remote Interfaces |
GPIB: IEEE Std 488.1 compliant; supports IEEE Std 488.2 common commands and status model topology
USB device (rear panel, type B): 2.0 full-speed USBTMC
USB host (front panel, type A): USB 2.0, support for flash drives, FAT32
Ethernet: RJ-45 connector, 10/100 BT |
IP Configuration |
Static or DHCP |
Expansion Interface |
The TSP-Link® expansion interface allows TSP-enabled instruments to trigger and communicate with each other |
LXI Compliance |
1.5 LXI Device Specification 2016 |
TSP Mode |
Embedded Test Script Processor (TSP) accessible from any host interface |
Display |
Five-inch capacitive touch, color TFT WVGA (800 × 480) with LED backlight |
Input Signal Connections |
Front: Banana. Rear: High-voltage triaxia |
Programmability |
SCPI or TSP command sets |
Interlock |
Active high-input |
Digital I/O |
Lines: Six input/output, user-defined, for digital I/O or triggering
Connector: 9-pin female D
Input Signal Levels: 0.7 V (maximum logic low), 3.7 V (minimum logic high)
Input Voltage Limits: –0.25 V (absolute minimum), +5.25 V (absolute maximum)
Maximum Source Current: +2.0 mA at > 2.7 V (per pin)
Maximum Sink Current: –50 mA at 0.7 V (per pin, solid-state fuse protected)
5 V Power Supply Pin: Limited to 500 mA at > 4 V (solid-state fuse protected)
Handler: User-definable start of test, end of test, four category bits |
Cooling |
Forced air, variable speed |
Overtemperature Protection |
Internally sensed temperature overload puts instrument in standby mode |
Power Supply |
100 VRMS to 240 VRMS, 50 Hz or 60 Hz (automatically detected at power up) |
VA Rating |
220 VA maximum |
Altitude |
Maximum 2000 meters (6562 feet) above sea level |
EMC |
Conforms to European Union EMC Directive |
Safety |
NRTL listed to UL61010-1 and UL61010-2-30; conforms to European Union Low Voltage Directive |
RoHS |
Conforms to European Union Restriction on Hazardous Substances Directive |
Vibration |
MIL-PRF-28800F Class 3 Random |
Warm up |
One hour to rated accuracies |
Dimensions |
With handle and bumpers: 106 mm × 255 mm × 425 mm (4.18 in. high × 10.05 in. wide × 16.75 in. deep)
Without handle and bumpers: 88 mm × 213 mm × 403 mm (3.46 in. high × 8.39 in. wide × 15.87 in. deep) |
Weight |
With handle and bumpers: 4.54 kg (10 lb)
Without handle and bumpers: 4.08 kg (9.0 lb) |
Environment |
Operating: 0 °C to 50 °C, 70% relative humidity up to 35 °C; derate 3% relative humidity/°C, 35 °C to 50 °C
Storage: –25 °C to 65 °C
Pollution Category: 2 |