Vertical |
Channels |
2 |
Bandwidth |
DC ~ 100MHz (-3dB) |
Rise Time |
<3.5ns Approx. |
Sensitivity |
2mV/div ~ 5V/div (1-2-5 increments) |
Accuracy |
?(3% x |Readout|+0.1 div + 1mV) |
Input Coupling |
AC, DC & Ground |
Input Impedance |
1M?2%, ~16pF |
Polarity |
Normal & Invert |
Maximum Input |
300V (DC+AC peak), CATII |
Waveform Signal Process |
+ , - , FFT |
Offset Range |
2mV/div ~ 50mV/div : ?0.4V
100mV/div ~ 500mV/div : ?4V
1V/div ~ 5V/div : ?40V |
Bandwidth Limit |
20MHz (-3dB) |
Trigger |
Sources |
CH1 , CH2 , Line , EXT |
Modes |
Auto, Normal, Single, TV, Edge, Pulse Width |
Coupling |
AC , DC , LF rej. , HF rej. , Noise rej. |
Sensitivity |
DC ~ 25MHz : Approx. 0.5div or 5mV |
Ext Trigger |
Range |
?15V |
Sensitivity |
DC ~ 30MHz : ~ 50mV
30M ~ 60MHz : ~100mV |
Input Impedance |
1MΩ?2% , ~ 16pF |
Maximum Input |
300V (DC AC peak) , CATII |
Horizontal |
Range |
1ns/div ~ 10s/div (1-2-5 increments); ROLL : 250ms/div ~ 10s/div |
Modes |
Main, Window, Window Zoom, Roll, X-Y |
Accuracy |
?0.01% |
Pre-Trigger |
10 div maximum |
Post-Trigger |
1000 div |
X-Y Mode |
X-Axis Input |
Channel 1 |
Y-Axis Input |
Channel 2 |
Phase Shift |
?3? at 100kHz |
Signal Aquisition |
Real-Time Sample Rate |
250MSa/s maximum |
Equivalent Sample Rate |
25GSa/s maximum |
Vertical Resolution |
8 Bits |
Record Length |
4K Dots maximum |
Acquisition Mode |
Normal, Peak Detect, Average |
Peak Detection |
10ns (500ns/div ~ 10s/div) |
Average |
2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 |
Cursors & Measurement |
Voltage Measurement |
Vpp , Vamp , V avg , Vrms , Vhi , Vlo , Vmax , Vmin , Rise Preshoot/Overshoot , Fall Preshoot/Overshoot |
Time Measurement |
Freq , Period , Rise Time , Fall Time , Positive Width , Negative Width , Duty Cycle |
Cursors Measurement |
Voltage difference between cursors (ΔV) |
Time difference between cursors (ΔT) |
Auto Counter |
Resolution : 6 digits
Accuracy : ?2%
Signal Source: All available trigger source except the Video trigger mode |
Control Panel Function |
Autoset |
Automatically adjusts Vertical VOLTS/DIV, Horizontal TIME/DIV, and Trigger level |
Save Setup |
Up to 15 sets of measurement conditions |
Save Waveform |
15 sets of waveform |
Display |
TFT LCD Type |
5.6 inch |
Display Resolution |
234 (Vertically) x 320 (Horizontally) Dots |
Display Graticule |
8 x 10 divisions |
Display Brightness |
Adjustable |
Interface |
USB Slave Connector |
USB1.1 & 2.0 full speed compatible (printers and flash disk not supported) |
SD Card Slot |
Image (BMP), waveform data (CSV), and setup (SET) |
Power Source |
Line Voltage Range |
AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection |
Miscellaneous |
Multi-Language Menu |
Available |
Online Help |
Available |
Accessories |
User manual x 1
Power Cord x 1
GTP-060A-2 Probe(10:1/1:1) x 2 |
Dimensions & Weight |
310(W) x 142(H) x 140(D)mm
Approx. 2.5kg |
Warranty |
Limited Lifetime |