Cleaning
LED TACFlux 007 may be removed using solvents, such as isopropyl alcohol, or standard semi-aqueous cleaning solvents. Indium Corporation’s Technical Support Engineers can recommend appropriate cleaning materials that are suitable for the application.
NOTE: LED die can be sensitive to the cleaning chemicals used to remove flux. The die supplier’s instructions on cleaning chemicals and cleaning procedures must be followed and should take precedence over the above guidelines.
Storage
For maximum shelf life, LED TACFlux 007 syringes and cartridges should be stored tip down. Storage temperatures should never exceed 30°C. After removing from cold storage, LED TACFlux 007 should be allowed to stand for at least four hours at room temperature before use.
Reflow
Reflow Atmosphere: A nitrogen (<100ppm oxygen) atmosphere is recommended.
Ramp Rate: A ramp rate of up to +5°C/second is recommended as a maximum.
Plateau: A plateau of 20-30 seconds at around 50°–60°C below the liquidus of the solder, while not essential, will help to remove volatile flux ingredients and reduce voiding in the final joint.
Peak Temperature: The peak temperature during reflow must not exceed the LED die manufacturer’s maximum allowed rating, and ideally, should be at least 20°C above the liquidus of the solder alloy. Standard alloys used in LED-attach are listed in the table below.
Cooling: A cooling rate of up to 10°C per second can typically be tolerated by LED die.