Transmitter |
Operating Frequency | 32 kilohertz, fixed-amplitude, time-modulated signal |
Current Output of Signal | 200mA p-pmax into 50 ohms |
Voltage Output of Signal | 30V nominal (2 watts) |
Operating Voltage | 0 – 600V AC/DC |
Fuse | 1A/1000V, High-Energy, Fast-Acting (6mm x 46mm) – IDEAL # F-958 |
Battery Power | 1.5V x (4) AA batteries (NEDA 15A, IEC LR6) |
Battery life | 40 hours open circuit testing / 25 hours short circuit tracing. |
Indicators | On/Off, Line energized, Low battery |
Receiver |
Sensing | Magnetic |
Maximum range | 15 feet underground. |
Signal response | Numeric display and Audible beep |
Battery Power | 1.5V x (3) AA batteries (NEDA 15A, IEC LR6) |
Battery life | 20 hours |
Inductive Clamp with Battery Pack |
Operating Frequency | 32 kilohertz, fixed-amplitude, time-modulated signal |
Current Output of Signal | 200mA p-pmax into 50 ohms |
Voltage Output of Signal | 30V nominal (2 watts) |
Operating Voltage | 0 – 600V AC/DC |
Battery Power | 1.5V x (8) C-cell batteries (NEDA 14A, IEC LR14) |
Battery life | 15 hours. |
Circuit Tracer Kits |
Operating Temperature | 32°F (0°C) to 122°F (50°C) |
Storage Temperature | -40°F (-4°C) to 154°F (90°C) (without batteries installed). |
Humidity (Operating) | 95% R.H. max |
Dimensions (W x H x D) | 61-954/956: 14.0 x 11.3 x 3.3 in. (355 x 285 x 83 mm) 61-958: 18.5 x 14.6 x 3.5 in. (470 x 371 x 89 mm) |
Weight | 61-954/956: 4.5 lbs. (2.1 kg) 61-958: 7.9 lbs. (3.6 kg) |
Accessories Included | Receiver, Transmitter, test lead kit, hard case, batteries, instruction manual. |
Safety | Complies with EN 61010-1, EN 61010-2-032, UL 61010-1, IEC 61010-2-032, IEC 61010-031 specifications, Cat III-1000V. |
Other Regularity | FCC Part 15 compliant, FCC recognized device.
|