Ideal 61-357 Specifications |
CAT Rating (Safety) |
CAT IV 600V | CAT III 1000V |
Listing |
cULus, CE, RCM |
Drop Protection |
6.6 ft. (2m) |
Ingress Protection |
IP52 |
AC Voltage (Volts) |
1,000V |
DC Voltage (Volts) |
1,000V |
AC Current (Amps) |
10A |
DC Current (Amps) |
10A |
Ohms (Resistance) |
60MΩ |
AC Millivolts |
6,000 |
DC Millivolts |
6,000 |
AC Milliamps |
6,000 |
DC Milliamps |
6,000 |
AC Microamps |
6,000 |
DC Microamps |
6,000 |
True RMS |
✓ |
High Voltage Alarm |
ACV/DCV | >30V |
Audible Continuity |
✓ |
Visual Continuity |
✓ |
Backlight |
✓ |
Temperature |
-40 ~ 1832°F | -40 ~ 1,000°C |
Low Impedance (LoZ) |
✓ |
NCV |
✓ |
Auto Ranging |
✓ |
Range Hold |
✓ |
Data Hold |
✓ |
Diode Test |
✓ |
Capacitance Test |
6,000 µF |
Frequency / Duty Cycle |
10Hz - 9.99 KHz |
Max / Min |
✓ |
Magnetic Strap Mount |
✓ |
Test Probe Holder |
✓ |
Auto-Power Off |
✓ |
APO Disable |
✓ |
Low Battery Indication |
✓ |
Battery Type (Included) |
3 x 1.5V AAA |
LCD Display Count |
6,000 |
Lead Warning |
✓ |
Fuse Notification |
✓ |
Bar Graph |
✓ |
Battery Test |
- |
Warranty |
2-Year* |
Accessories |
Leads, Case & Temp. Sensor |
Included |
Electrical Specifications |
Function |
Range
61-347 & 61-357 |
Resolution |
Accuracy |
±(a%+b) |
AC Voltage (V) ARMS
(61-357 has LoZ) |
600mV |
0.1mV |
±(1.5%+8) |
6V |
0.001V |
±(1.3%+5) |
60.00V |
0.01V |
600.0V |
0.1V |
1000V |
1.0V |
±1.5%+5) |
AC Current (A) TRMS |
600.0μA |
0.1μA |
±(2%+5) |
6,000μA |
1μA |
60.00mA |
0.01mA |
600.0mA |
0.1mA |
6.000A |
0.001A |
±(2.5%+5) |
10.00A |
0.01A |
DC Voltage (V) |
600mV |
0.1mV |
±(1.5%+8) |
6V |
0.001V |
±(1.3%+5) |
60.00V |
0.01V |
600.0V |
0.1V |
1,000.0V |
1V |
±(1.5%+5) |
DC Current (A) |
600.0μA |
0.1μA |
±(2%+5) |
6,000μA |
1μA |
60.00mA |
0.01mA |
600.0mA |
0.1mA |
6.000A |
0.001A |
±(2.5%+5) |
10.00A |
0.01A |
Resistance (Ω) |
600.0Ω |
0.1Ω |
±(1.5%+5) |
6.000kΩ |
0.001kΩ |
60.00kΩ |
0.01kΩ |
600.0kΩ |
0.1kΩ |
±(2%+5) |
6.000MΩ |
0.001MΩ |
60.00MΩ |
0.01MΩ |
Capacitance |
600.0nF |
0.1nF |
±(5%+15) |
6.000uF |
0.001uF |
60.00uF |
0.01uF |
600.0uF |
0.1uF |
6,000uF |
1uF |
±10% |
Frequency Hz |
9.999Hz ~ 9.999KHz |
0.001Hz ~ 0.1KHz |
±(0.5%+5) |
Duty Cycle % |
0.1%~99.9% |
0.1% |
|
Temp. °F |
-40~1,832°F |
1°F |
±(2.0%+7)@-40~32°F
±(2.0%+6)@33~1,832°F |
Temp. °C |
-40~1,000°C |
1°C |
±(2.0%+4)@-40~0°C
±(2.0%+3)@1~1,000°C |
Continuity |
|
0.1 Ω |
≤10Ω : Buzzer beeps and red indicator LED illuminates continuously |
≥70Ω : No buzzer beep |
Diode test |
|
0.001V |
Silicon PN joint with forward voltage about 0.5V to 0.8V |
NCV |
40-600V |
≥40V/(50~60Hz), with direct wire contact, red indicator LED flashes at a frequency of 3Hz, and the buzzer beeps at a frequency of 3Hz simultaneously |
1. Overload Protection: 1,000VRMS MAX Fuses FF 0.6A 1,000V and F 11 A 1,000V. |
2. Accuracy a is % of reading and b is LSD (Least Significant Digit). |
Environmental Specifications |
Operating Temperature: |
32ºF to 86ºF (0ºC to 30ºC) (80%RH)
86ºF to 140ºF (30ºC to 40ºC) (75%RH)
104ºF to 122ºF (40ºC to 50ºC) (45%RH) |
Operating Altitude: |
< 6,500 ft (< 2,000 m) |
Storage Temperature: |
14ºF to 140ºF (-10ºC to 60ºC) (<80%RH) |
Intended for indoor use |
Mechanical Specifications |
Dimensions (L x W x H) |
7.83 in. x 3.74 in. x 2.24 in.
(199 mm. x 95 mm. x 57 mm.) |
Weight |
1.147 LBS (0.52 KG) |
Display |
LCD |
Display Count |
6,000 |
Power Source |
3 x 1.5V AAA |
Battery Life |
100 Hours Typical |
Safety |
Complies with the following:
UL 61010-1, 3rd Edition, May 11, 2012, Revised November 21 2018, CAN/
CSA-C22.2 No. 61010-1-12, 3rd Edition, Amendment 1:2018, Revision dated
November 21 2018,
IEC 61010-2-033: 2019
Overvoltage CAT III 600V
Any voltages exceeding the defined maximum voltage measurement categories
described above are outside the normal use of the equipment and protection cannot be guaranteed.
Pollution Degree Class 2 |
EMC/EMI |
CISPR 22 3rd Edition. Class B Limits.
EN 55032
CISPR 32
CISPR 11
FCC 15. 107 with reference to Section 15.109 (g).
ICES-003
EN 61326-2-2 Sec 6.4.2.101 |
USA(FCC) |
47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103. |
Maintenance and Service |
Equipment Maintenance and Service Meter Inspection |
Do not use if meter appears damaged. Visually inspect the meter to ensure the case is not cracked. |
Test Lead Inspection |
Inspect and replace test leads if insulation is damaged, metal is exposed, or probes are cracked. Pay particular attention to the insulation surrounding the connectors. |
Thermocouple Inspection |
Inspect the thermocouple for signs of wear or breakage. Replace if necessary to guarantee accuracy of readings. |