AC Current range |
42.00 to 1000 A AC, 3 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Average rectifier effective value |
AC Voltage range |
4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Average rectifier effective value |
DC Voltage range |
420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.) |
Other functions |
Resistance: 420.0 to 42.00 M-ohm, 6 ranges, Accuracy: ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range), Continuity: 420.0 ohm (Buzzer sounds at approx. 50 ohm or less) |
Frequency characteristics |
(at AC current / voltage) AC current: 50/60 Hz, AC voltage: 50 to 500 Hz |
Display section |
Digital / LCD, maximum 4199 dgt. |
Sampling rate |
2.5 times/sec or 1 times/3 sec |
Max. circuit voltage |
600 V AC rms (insulated wire) |
Power supply |
CR2032 (3 VDC) × 1, Continuous use 150 hours |
Core jaw diameter |
Ø 33 mm(1.30 in) |
Dimensions |
57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (22.44 oz) |
Accessories Included |
TEST LEAD 9208 (1), CARRYING CASE 9398 (1) |
LCD panel |
4199 maximum display value |
Out of range indication |
OF or -OF |
Battery low warning |
(during which time accuracy cannot be guaranteed). |
Data hold indication |
|
Zero suppression |
5 count or less (current measurement only) |
Display update interval |
FAST: 400 ms ±25 ms, SLOW: 3.2 s ±0.2 s |
Range switching |
Auto range / Manual range |
Withstand voltage |
Between case and circuit: AC4290 Vrms for 1 min.
Between clamp sensor and case: AC7060 Vrms for 1 min.
Between clamp sensor and circuit: AC5400 Vrms for 1 min. |
Location of use |
Altitude up to 2000 m (6562 feet), indoors, Pollution Degree 2 |
Maximum conductor
diameter for measurement |
φ33 mm (1.30") or less |
Operating temperature
and humidity |
0 to 40°C (32 to 104°F), 80%RH max (no condensation) |
Storage temperature |
-10 to 50°C (14 to 122°F) (no condensation) |
Temperature characteristics |
In 0 to 40°C (32 to 104°F) range: 0.1 x Measurement accuracy / (°C) |
Power supply |
Lithium battery: CR2032 x 1 (Rated supply voltage 3 V DC) |
Maximum rated power |
15 mVA |
Continuous operating time |
Approx. 150 hours (standard), Approx. 80 hours min. (in AC
current measurement mode, continuous, no load) |
Dimensions and mass |
Approx. 57W x 175H x 16D mm, approx. 100 g
(Approx. 2.24"W x 6.89"H x 0.63"D, approx. 3.5 oz.) |
Drop proof |
One meter to concrete |
Accessories |
Instruction manual, 9398 Carrying Case, L9208 Test Leads |
Maximum rated voltage to earth |
Current measurement section:
Measurement category CAT III 600 V
(anticipated transient overvoltage 6000 V)
Voltage measurement section:
Measurement Category CAT III 300 V, CAT II 600 V
(anticipated transient overvoltage 4000 V) |
Applicable standards |
Safety :EN61010
EMC :EN61326 |