DC VOLTAGE |
Range |
0.1 ÷ 999.9V |
Resolution |
0.1V |
Accuracy |
±(1.0%rdg + 3dgt) |
Input impedance |
1MΩ |
Overload protection |
1000VDC/ACrms |
AC (AC+DC) TRMS VOLTAGE |
Accuracy |
±(1.0%rdg + 3dgt) |
Input impedance |
1MΩ |
Overload protection |
1000VDC/ACrms |
Max crest factor |
1.41 |
Fundamental |
50/60Hz ± 15% |
Frequency bandwidth |
42.5Hz ÷ 1725Hz |
AC/DC VOLTAGE – MAX/MIN/CREST |
Range |
0.5 ÷ 999.9V |
Resolution |
0.1V |
Accuracy |
±(3.5%rdg + 5dgt) |
Response time |
1s |
Overload protection |
1000VDC/ACrms |
Input impedance |
1MΩ |
Max crest factor |
1.41 |
Fundamental |
50/60Hz ± 15% |
Frequency bandwidth |
42.5Hz ÷ 1725Hz |
DC CURRENT |
Range |
0.1 ÷ 999.9A |
Resolution |
0.1A |
Accuracy |
±(2.0%rdg + 5dgt) |
Overload protection |
1000ADC/ACrms |
AC (AC+DC) TRMS CURRENT |
Range |
0.1 ÷ 999.9A |
Resolution |
0.1A |
Accuracy |
±(2.0%rdg + 5dgt) |
Overload protection |
1000ADC/ACrms |
Max crest factor |
1.41 |
Fundamental |
50/60Hz ± 15% |
Frequency bandwidth |
42.5Hz ÷ 1725Hz |
AC/DC CURRENT – MAX/MIN/CREST |
Range |
0.5 ÷ 999.9A |
Resolution |
0.1A |
Accuracy |
±(3.5%rdg + 5dgt) |
Response time |
1s |
Overload protection |
1000VDC/ACrms |
Max crest factor |
1.41 |
Fundamental |
50/60Hz ± 15% |
Frequency bandwidth |
42.5Hz ÷ 1725Hz |
DYNAMIC INRUSH CURRENT DC, AC+DC TRMS |
Range |
1.0 ÷ 99.9A |
Resolution |
0.1A |
PEAK Accuracy |
±(2.0%rdg + 5dgt) |
Max RMS Accuracy |
±(2.0%rdg + 5dgt) |
Overload protection |
1000ADC/ACrms |
Crest factor |
3 |
Sample frequency |
4kHz |
Response time |
Peak: 1ms |
Max RMS |
calculated on: 16.7, 20, 50, 100, 150, 200ms |
Accuracy declared for frequency |
DC, 42. .. 69Hz |
RESISTANCE AND CONTINUITY TEST |
Range |
0.0Ω ÷ 199.9Ω, 200Ω ÷ 1999Ω, 2.00kΩ÷19.99kΩ, 20.0kΩ ÷ 29.9kΩ |
Resolution |
0.1Ω, 1Ω, 0.01kΩ, 0.1kΩ |
Accuracy |
±(1.0%rdg + 5dgt) |
Buzzer |
1Ω ÷ 150Ω |
Overload protection |
1000VDC/Acrms, 1000ADC/ACrms |
FREQUENCY WITH TEST LEADS AND WITH JAWS |
Range |
42.5 ÷ 69.0Hz |
Resolution |
0.1Hz |
Accuracy |
±(1.0%rdg + 5dgt) |
Overload protection |
1000VDC/Acrms, 1000ADC/ACrms |
Voltage range for frequency measurement |
0.5 ÷ 1000V / Current range for frequency measurement with jaws : 0.5 ÷ 1000A |
PHASE SEQUENCE AND PHASE CONFORMITY |
Voltage range |
100 ÷ 1000V |
Frequency range |
42.5 ÷ 69Hz |
Overload protection |
1000VDC/ACrms |
Input impedance |
1MΩ |
DC POWER |
Range [kW] |
0.00 ÷ 99.99, 100.0 ÷ 999.9 |
Resolution [kW] |
0.01, 0.1 |
Accuracy |
±(3.0%rdg + 3dgt) |
Input impedance |
1MΩ, Accuracy defined for voltage > 10V, current ≥ 2A |
ACTIVE POWER, APPARENT POWER AC (AC+DC TRMS) |
Range [kW, kVA] |
0.00 ÷ 99.99, 100.0 ÷ 999.9 |
Resolution [kW, kVAR, kVA] |
0.01, 0.1 |
Accuracy |
±(2.0%rdg + 3dgt) |
Input impedance |
1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.5 |
REACTIVE POWER AC (AC+DC TRMS) |
Range [kVAR] |
0.00 ÷ 99.99, 100.0 ÷ 999.9 |
Resolution [kW, kVAR, kVA] |
0.01, 0.1 |
Accuracy |
±(2.0%rdg + 3dgt) |
Input impedance |
1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.9 |
ACTIVE ENERGY AC (AC+DC TRMS) |
Range [kWh] |
0.00 ÷ 99.99, 100.0 ÷ 999.9 |
Resolution [kWh] |
0.01, 0.1 |
Accuracy |
±(2.0%rdg + 3dgt) |
Input impedance |
1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.5 |
REACTIVE ENERGY AC (AC+DC TRMS) |
Range [kVARh] |
0.00 ÷ 99.99, 100.0 ÷ 999.9 |
Resolution [kVARh] |
0.01, 0.1 |
Accuracy |
±(2.0%rdg + 3dgt) |
Input impedance |
1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.9 |
Range |
0.20 ÷ 1.00 |
Resolution |
0.01 |
Accuracy |
±(2.0%rdg+2dgt) |
Input impedance |
1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A |
VOLTAGE AND CURRENT HARMONICS |
Harmonic order |
0, 1 ÷ 25, THD% |
Fundam. Freq. [Hz] |
42.5 ÷ 69.0 |
Resolution [V], [A] |
0.1V /0.1A, 0.1% |
Accuracy (values not zeroed) |
±(5.0%rdg+20dgt), ±(5.0%rdg+10dgt), ±(10.0%rdg+10dgt) |
Mechanical characteristics |
Dimensions (L x W x H) |
252 x 88 x 44mm |
Weight (including battery) |
420g |
Max conductor size |
45mm |
Power supply |
Battery type |
2 batteries 1.5V type AAA IEC LR03 |
Battery life |
approx. 150 hours of continuous use in power/energy measures |
Auto Power Off |
approx. 5 minutes of idleness |
Display |
Characteristics |
graphic dot matrix, 128x128pxl with backlight |
Sample rate |
128 samples/period (@ 50Hz) |
Display update rate |
1 times/sec |
Conversion mode |
TRMS |
Climatic conditions |
Reference temperature |
23°C ± 5°C |
Operating temperature |
0 ÷ 40 °C |
Operating humidity |
<80%RH |
Storage temperature |
-10 ÷ 60 °C |
Storage humidity |
<70%RH |
Reference guidelines |
Comply with |
IEC/EN 61010-1, IEC/EN61010-2-032 |
EMC |
IEC/EN61326-1 |
Safety of test leads |
IEC/EN61010-031 |
Insulation |
double insulation |
Pollution degree |
2 |
For inside use, max height |
2000m |
Installation category |
CAT IV 600V to ground, max 1000V between inputs |
Normative |
EMC 2004/108/CE Directive, LVD 2006/95/CE Directive, IEC/EN 61010-1, IEC/EN61187, CE MARK, EMC: IEC/EN61326 |