PROFITEST |
MPRO |
MTECH+ |
MXTRA |
|
|
|
|
RCD measurements |
|
|
|
UB measurement without tripping the RCD |
x |
x |
x |
Tripping time measurement |
x |
x |
x |
Tripping current measurement |
x |
x |
x |
Selective, SRCDs, PRCDs, type G/R |
x |
x |
x |
AC/DC sensitive RCDs, types B and B+ |
- |
x |
x |
Testing of insulation monitoring devices (IMDs) |
- |
- |
x |
Testing of residual current monitoring devices (RCMs) |
- |
-- |
x |
Testing for N-PE reversal |
x |
x |
x |
Loop impedance ZL-PE / ZL-N |
|
|
|
Fuse table for systems without RCDs |
x |
x |
x |
Without tripping the RCD, fuse table |
- |
x |
x |
With 15 mA test current without tripping the RCD |
x |
x |
x |
Earth resistance |
|
|
|
Earth resistance RE (mains operation)
I/U measuring method (2/3-wire measuring method
via measuring adapter: 2-wire/2-wire + probe) |
x |
x |
x |
Earth resistance RE (battery operation)
3 or 4-wire measuring method via PRO-RE adapter |
x |
- |
x |
Soil resistivity ρE (battery operation) (4-wire measuring method via PRO-RE adapter) |
x |
- |
x |
Selective earth resistance RE (mains operation) with 2-pole adapter, probe, earth electrode and current clamp sensor (3-wire measuring method) |
x |
x |
x |
Selective earth resistance RE (battery operation) with probe, earth electrode and current clamp sensor (4-wire measuring method) via PRO-RE adapter and current clamp sensor) |
x |
- |
x |
Earth loop resistance ρEloop (battery operation) with 2 clamps (current clamp sensor direct and current clamp transformer via PRO-RE/2 adapter) |
x |
- |
x |
Equipotential bonding measurement RLO
with automatic polarity reversal |
x |
x |
x |
Insulation resistance RISO
with variable or rising test voltage (ramp) |
x |
x |
x |
Variable or rising test voltage |
x |
x |
x |
Voltage measurement
UL-N / UL-PE / UN-PE / f |
x |
x |
x |
Special measurements |
|
|
|
Leakage current (clamp meter meas.) IL, IAMP
Phase sequence
Earth leakage resistance RE(ISO)
Voltage drop
Standing surface insulation ZST
Meter start-up |
x
x
x
x
x
x |
x
x
x
x
x
x |
x
x
x
x
x
x |
Leakage current with PRO-AB adapter |
- |
- |
x |
Residual voltage test |
- |
- |
x |
Intelligent ramp |
- |
- |
x |
Features |
|
|
|
Selectable user interface language |
x |
x |
x |
Memory (database for up to 50,000 objects) |
x |
x |
x |
Automatic test sequence function (programable) |
x |
x |
x |
RS 232 port for RFID/barcode scanner |
x |
x |
x |
USB port for data transmission |
x |
x |
x |
Interface for Bluetooth |
- |
x |
x |
User software for PC: ETC (for non-IQ),
- IZYTRONIQ BUSINESS Starter (for IQ) |
x |
x |
x |
Measuring category: CAT III 600V / CAT IV 300V |
x |
x |
x |
DAkkS calibration |
x |
x |
x |
Article number for IQ:
without IQ: |
M535C
M520N |
M535B
M520R |
M535D
M520P |
PROFITEST |
MPRO |
MTECH+ |
MXTRA |