Specifications: |
AC Voltage Measurement Range |
0 to 750V |
AC Voltage Measurement Accuracy |
±0.6% of reading ±3 digits from 0 to 400V;
±1% of reading from 400 to 750V |
DC Voltage Measurement Range |
0 to 1000V |
DC Voltage Measurement Accuracy |
±0.6% of reading ±2 digits from 0 to 400V;
±0.8% of reading from 400 to 1000V |
AC Current Measurement Range |
0 to 400mA |
AC Current Measurement Accuracy |
±0.15% of reading ±5 digits |
DC Current Measurement Range |
0 to 400mA |
DC Current Measurement Accuracy |
±0.15% of reading ±3 digits (A range);
±0.15% of reading ±5 digits (mA range) |
Resistance Measurement Range |
0.4Ω to 40MΩ |
Resistance Measurement Accuracy |
0.4 to 400KΩ, 0.7% ±3 digits, 400K to 40MΩ, 2% ±6 digits |
Capacitance Measurement Range |
52nF to 100?F |
Capacitance Measurement Accuracy |
52nF to 5.2?F, 3% ?3 digits, 52?F to 100?F, 10% ±6 digits |
Non-Contact AC Voltage Detection Range |
10V to 1000V |
Non-Contact AC Current Detection Range |
100mA to 1000A |
Wireless Link Type/Frequency |
Half-duplex/2.4 GHz |
Wireless Range/Channel Options |
33 ft. (10m)/10 channels |
Maximum Line Voltage/Current |
120VAC/15A |
Operating Temperature |
32° to 113°F (0° to 45°C) @ <80% RH |
Dimensions |
7.09 x 3.74 x 2.13 in. (180 x 95 x 54mm) |
Weight (w/out battery) |
15.9 oz. (450g) |
Power Source |
1 "9V" battery |