Look to CertiFiber to test more fibers in less time. With its one-button Autotest, CertiFiber allows you to measure fiber length and optical loss on two fibers at two wavelengths, compares the results to the selected industry standard and provides an instant PASS or FAIL indication. CertiFiber connects easily to all fiber networks with interchangeable connector adapters.
Interchangeable Connector Adapters
CertiFiber's interchangeable connector adapters permit simple network connection and a straightforward reference power measurement. Interchangeable connector adapters are available in the most popular connector styles: ST, SC, FC and 1.25mm universal.
Bi-directional Testing
Utilizing CertiFiber's dual-fiber measurement method, when placed in bi-directional test mode, CertiFiber measures the fiber pair in one direction. It then prompts you to swap connections at the patch panel or outlet and proceeds to measure the fiber pair in the other direction. Unlike the traditional power meter and light source combination, you do not need to swap CertiFiber's main and remote test units, providing tremendous time-savings for each fiber link tested.
Using loopback mode, CertiFiber's main unit can function independently from the remote. Loopback mode is useful when measuring a single fiber on a reel or spool since both fiber ends must be near one another.
PASS/FAIL Analysis
CertiFiber takes the guesswork out of interpreting test results. The length and loss test results are automatically compared against a standard you selected. CertiFiber instantly provides a clear PASS or FAIL indication for each fiber. The margin (or headroom) between the test measurement and standards limit is also presented.
You can certify your network to various industry standards. Select the appropriate standard from CertiFiber's built-in library. The library contains the most common standards including TIA-568, ISO 11801, 10BASE-X and 1000-BASE-SX and it allows you to create your own custom test standards.
Length and Loss Measurement
CertiFiber measures fiber length using the "time of flight" technique where an optical pulse is launched into the fiber under test. The time that it takes for that pulse to return to its launch point is measured. This round-trip travel time is also called propagation delay.
Since we know the speed of light in a fiber, it is simple to convert this time into a length measurement. The advantages of this length measurement technique include simplicity (no launch cables, no cursors to set) and accuracy, especially with short lengths (zero dead zone).
CertiFiber also measures optical power and loss at 850 nm and 1300 nm and reference measurements are easy to perform. Simply connect the main and remote units, press the Set Reference button, and CertiFiber automatically measures and records the reference power for both fibers at both wavelengths.
One-button Autotest
Save time and increase productivity
CertiFiber cuts your test time by 75% over manual power meter techniques while certifying your fiber links in seconds with a touch of the Autotest button.
The transmitter ports of the main and remote CertiFiber units incorporate dual wavelength LED sources. Test both fibers at the multimode fiber transmission wavelengths of 850 nm and 1300 nm. Dual wavelength testing occurs automatically - no need to slow down to physically change transmitter adapters or manually toggle between wavelengths. CertiFiber auto-senses the transmitted wavelength, making testing even easier.
Every CertiFiber kit includes a pair of main and remote units. Both units incorporate transmitter and detector ports. This unique configuration enables testing of two fibers in a single operation. This design is ideal for testing typical fiber links - a pair of Tx/Rx fibers. CertiFiber is also suitable for testing dual-fiber Small Form Factor connector systems.
Multimode Fiber Mandrels
Look to Fluke Networks' Multimode Fiber Mandrels for TIA/EIA compliant multimode fiber mandrels.
Fluke Networks' Multimode Fiber Mandrels offer a simple, cost effective way to:
- Improve the repeatability and consistency of multimode optical power and loss measurements when using a LED source and 3.0 mm test jumpers
- Ensure that your measurements are compliant with TIA/EIA-568-B standards
- Guarantee the correct number of wraps around the proper diameter mandrel
- Protect 3.0 mm fiber cable from damage and unwanted microbends
Fluke Networks' multimode fiber mandrels provide a foolproof, cost-effective method of improving the repeatability and consistency of multimode optical power and loss measurements when using an LED source. Our mandrels guarantee the correct number of wraps of the appropriate diameter as specified by the TIA/EIA-568-B standard while protecting 3 mm fiber cables from damage and preventing unwanted microbends.
Fluke Networks' multimode fiber mandrels feature grooves that enable the user to wrap the source test jumper five times around the mandrel. A retainer keeps the cable in place while not crushing the fiber - making its use foolproof.
The fiber mandrels are sized for 3.0 mm fiber cables - the most commonly used jumper cable type in the industry. A red 22 mm mandrel is available for 50/ 125?m fiber and a 17 mm grey mandrel is available for 62.5/125?m fiber.
LinkWare? Cable Test Management Software
Manage copper and fiber test results with LinkWare software
Fluke Networks' powerful LinkWare Software helps you quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more. You can merge test results into an existing database and then sort, search and organize by any number of data fields or parameters.
LinkWare is available free from our web site. Once your work is done, you can give this powerful application to your customer so they can have instant access to the data electronically or you can export the data as an Adobe Portable Document Format (PDF).
Extensive data management capabilities with LinkWare:
- Manage copper and fiber test results with a single software application that supports Fluke Networks' entire line of cable testers
- Deliver professional, customized, graphic reports in a common format for all Fluke Networks cable testers
- Ensure standards compliance with the ability to configure and print TIA 606-A documentation
- New drag and drop feature makes it easier to manage and organize multiple projects
- Count on compatibility with major CMS (cable management software) applications
- Increase productivity with simple user interface and time-saving features with LinkWare, the world's preferred cable test management software
LinkWare Software prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.