General Specifications |
Operating Temperature |
-30 – 50°C (-22 – 122ºF) (full power) |
Operating Humidity |
5 – 95% (non-condensing) |
Storage |
-40 – 85°C (-40 – 185ºF), 5 – 95% RH (non-condensing) |
Cooling |
Free-air convection (no fans; fully enclosed, IP65) |
Altitude |
3,962 m (13,000 ft), max |
Vibration |
10 – 55 Hz, 2 G, 3 min period, 60 min each (3 axes) |
Shock |
20 G peak acceleration |
Reliability |
368 K Hours @ 50°C (122ºF) (per MIL STD 217F) |
Dimensions |
174 x 76 x 429.5 mm (6.85 x 3 x 16.9 in.) |
Weight |
4.7 kg (10.3 lbs.) |
Input Specifications |
Voltage |
85 – 132 VAC |
Frequency |
45 – 63 Hz |
Inrush |
≤ 25 A @ 120 VAC full load |
Current |
≤ 5 A @ 230 VAC (Max Continuous) |
Leakage |
< 3.5 mA @ 132 VAC |
Efficiency |
>91% typical @ ≥ 50% load (pending verif.) |
Hold-Up |
20 ms minimum @ 120 VAC |
Harmonics |
EN61000-3-2 Class D (>0.99 PF; > 50% load) |
Output Specifications |
Output Voltage |
48 VDC (typical) |
Output Current |
6 A (max, continuous) |
Line Regulation |
±1.0%, across full input range |
Load Regulation |
±3.0%, across full load range |
Ripple |
≤100 mV p-p; ≤ 10 mVrms (20 MHz BW) |
Output Adjustment |
TBD |
Excursion |
TBD |
Recovery |
TBD |
Over-Current |
110 – 160% (8.5 – 9.6 A);Auto-Recovery |
Protection |
OVP Shutdown: 110 – 140% (Auto-Restart)
Over-Temp Shutdown: 80 ± 10°C (Auto-Restart @ 50°C/122ºF) |
Emissions |
Emissions |
FCC Part 15 Class B (Conducted) |
Electrostatic Discharge |
EN61000-4-2, 4 kV Contact/ 8KV Air |
Radiated Susceptibility |
EN61000-4-3, 26 MHz - 2000 MHz, 10 V/M, 80% AM |
EFT/Bursts |
EN61000-4-4, 2 kV |
Surge |
EN61000-4-5, 2 kV Earth, 1 kV Line-Line |
Conducted Immunity |
EN61000-4-6, 150-800 MHz, 10 V 80% |
Voltage Dips |
EN61000-4-10, 95% Dip, 10 ms / 30% Dip, 500 ms |
Voltage Interruptions |
EN61000-4-11, 95% reduction, 5 ms |
Fluctuations & Flicker |
EN61000-3-3 |
Safety Standards |
UL/cUL |
Designed to meet IEC/UL 60950-1 (pending) |
CE Mark |
Designed to meet low voltage directive (pending) |