Digilent Data Recorders

 
Digilent MCC USB-1024HLS - 24 Channel High-Current Digital I/O USB Device
Catalog: 6069-410-034
  • # Channels Expanded plus Logic (Recorders): 24 EA
  • Interfaces I/O: Other
  • Product Height: 12 IN
  • Product Length: 4.8 IN
  • Product Width: 0.8 IN
  • Shipping Weight: 2 LBS

Your Price: $199.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent MCC USB-1024LS - 24 Channel Digital I/O USB Device
Catalog: 6069-410-053
  • Type (Recorders): DAQ System
  • Power Source: USB Powered
  • Safety Approval: CE
  • Interfaces I/O: USB
  • Product Height: 2.32 IN
  • Product Length: 13.5 IN

Your Price: $119.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent MCC USB-1808X - High-Speed, High-Precision, Simultaneous USB DAQ Device (18-bit, 200 kS/s/ch)
Catalog: 6069-410-014
  • Type (Recorders): DAQ System
  • Style (Recorders): PC Based
  • Power Source: USB Powered
  • Interfaces I/O: Analog Output, Other
  • Product Height: 1.40 IN
  • Product Length: 5 IN

Your Price: $989.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent MCC USB-205 - Single Gain Multifunction USB DAQ Device: 12-bit, 500 kS/s
Catalog: 6069-410-009
  • Type (Recorders): DAQ System
  • Style (Recorders): PC Based
  • Display (Recorders): Optional Purchase
  • Input Types (Controllers/Recorders): Voltage
  • Product Height: 1.14 IN
  • Product Length: 4.64 IN

Your Price: $209.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent MCC USB-231 - Multifunction USB DAQ Device (16-bit, 50 kS/s)
Catalog: 6069-410-012
  • Type (Recorders): DAQ System
  • Interfaces I/O: Other, Analog Input
  • Product Weight: 3.7 OUNCES (0.231 LBSWhat's This?)
  • Product Height: 3.67 IN
  • Product Length: 3.4 IN
  • Product Width: 0.93 IN

Your Price: $289.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent WebDAQ 504 - Internet Enabled Vibration-Acoustic Data Logger
Catalog: 6069-410-006-1
  • Type (Recorders): DAQ System
  • Style (Recorders): Behind Panel / DIN Rail Mount, Bench / Portable, PC Based
  • # Channels Base Unit (Recorders): 4 EA
  • Display (Recorders): N/A
  • Sampling Interval (Controllers/Recorders): 51 ms
  • Sampling Frequency (Recorders): 51 kS/S (0.051 MS/SWhat's This?)

Your Price: $1,569.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent WebDAQ 904 - Internet Enabled Universal Input Data Logger
Catalog: 6069-410-007-1
  • Type (Recorders): DAQ System
  • Style (Recorders): Behind Panel / DIN Rail Mount, Bench / Portable
  • # Channels Base Unit (Recorders): 4 EA
  • Display (Recorders): N/A
  • Sampling Frequency (Recorders): 100 S/s (0.0001 MS/SWhat's This?)
  • Input Types (Controllers/Recorders): Current / 4-20 mA, Frequency / Pulse, T/C - RTD, Voltage

Your Price: $1,569.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent 6069-471-001 - High-Precision Thermocouple Measurement USB/Ethernet System (TC-32 and TC-32-EXP)
Catalog: 6069-471-001
  • Sampling Frequency (Recorders): 3 S/s (0.000003 MS/SWhat's This?)
  • Unique Features: TC-32 and TC-32-EXP
  • Interfaces I/O: LAN / Ethernet, Other, USB
  • Product Height: 19 IN
  • Product Length: 6.15 IN
  • Product Width: 1.74 IN

Your Price: $4,058.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent DT8874-00T-00R-16V - Measuring Ethernet DAQ Instrument (16 V Inputs)
Catalog: 6069-410-221
  • Type (Recorders): DAQ System
  • Style (Recorders): PC Based
  • # Channels Base Unit (Recorders): 16 EA
  • Input Types (Controllers/Recorders): T/C - RTD, Voltage
  • Output Types (Controllers/Recorders): Relay
  • Power Source: AC Line

Your Price: $5,935.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent DT8874-00T-00R-48V - MEASURpoint Ethernet DAQ Instrument (48 V Inputs)
Catalog: 6069-410-225
  • Type (Recorders): DAQ System
  • Style (Recorders): PC Based
  • # Channels Base Unit (Recorders): 48 EA
  • Input Types (Controllers/Recorders): T/C - RTD, Voltage
  • Output Types (Controllers/Recorders): Relay
  • Power Source: AC Line

Your Price: $10,545.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent DT8874-00T-16R-32V - MEASURpoint Ethernet DAQ Instrument (16 RTD Inputs, 32 V Inputs)
Catalog: 6069-410-228
  • Type (Recorders): DAQ System
  • Style (Recorders): Behind Panel / DIN Rail Mount, Bench / Portable
  • # Channels Base Unit (Recorders): 48 EA
  • Input Types (Controllers/Recorders): T/C - RTD, Voltage
  • Output Types (Controllers/Recorders): Relay
  • Power Source: AC Line

Your Price: $10,545.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Digilent DT8874-00T-40R-08V - MEASURpoint Ethernet DAQ Instrument (40 RTD Inputs, 8 V Inputs)
Catalog: 6069-410-231
  • Type (Recorders): DAQ System
  • Style (Recorders): Behind Panel / DIN Rail Mount, Bench / Portable
  • # Channels Base Unit (Recorders): 48 EA
  • Input Types (Controllers/Recorders): T/C - RTD, Voltage
  • Output Types (Controllers/Recorders): Relay
  • Power Source: AC Line

Your Price: $10,545.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Digilent Data Recorders

Data Recorders (or Dataloggers, Data Acquisition) refers to electronics designed to capture analog signals or measurements over time for study and review later.

Benefits of Dataloggers/Data Recorders
  • Quiet, unattended 24/7 operation
  • Simple to setup and operate. Many portable models available
  • Wide variety of measurement types and measurement speeds possible
  • Help troubleshoot and identify problems in many fields
  • Steady declining cost
Parts of a Datalogger/Data Recorder
  • Built in sensor, such as temperature, or electrical terminals to connect an external one
  • A/D or analog to digital converter and signal conditioning electronics
  • Non-volatile storage memory for the collected data and a method to specify the storage rate and on some models the scan interval
  • PC Communications or other method to move the data to a computer and to configure the unit
  • Optionally a local display and keypad. Not always needed, so “blind” units are a cost saving
  • Optional Outputs. More advanced units may have alarm relays or can re-transmit signals to other equipment
My handheld Digital Thermometer logs so is it considered a Datalogger?

For our website purposes, no. We further classify data logging instruments as dedicated to data logging. Typically they will be “blind”, i.e. no display or buttons, and intended for long term unattended operation. A handheld digital thermometer will have a host of other features, one of which may optionally be to record data. We have categorized these measuring instruments here Products > Thermometers.

What is the difference between data logging and data acquisition or data recording?

Data logging is a subset of data acquisition/data recording. While some may use the terms interchangeably, there are differences. Here is a list of notable differences. Of course, there will be exceptions, but dataloggers or data recorders will have most of the characteristics from their respective list below:

Typical datalogger characteristics:
"USBdatalogger"
  • Handheld or portable instruments
  • Many have a built-in sensor
  • Measuring one or two variables
  • Slow rates compared to data recorders.
Typical data acquisition system and data recorder characteristics:

"DAX-network"
  • Bench instruments
  • Imagine digital replacements of the paper chart recorder
  • Sampling rates better than 1 Hz
  • Multi-channel capabilities from 1-2 to hundreds
  • Have a built in real-time clock for more accurate time stamps
  • Often have network connectivity
  • Many are AC powered and built to withstand power fluctuations and continue logging
  • May have a local display replacing the traditional paper chart. These are called videographic recorders
X