Desco 50571 Specifications |
Performance |
Monitored Voltage Range |
0 to ±1100 V DC or peak AC. |
Small Signal Bandwidth (-3 dB) |
DC to 1 kHz (measured at 20 V p-p). |
Large Signal Bandwidth |
DC to 10 Hz (measured at 2000 V p-p). |
Zero Stability (referred to plate voltage) |
Drift with Time (no incident ion flow) |
Less than 6 V/minute. |
Drift with Temperature |
Less than 10 mV/°C, noncumulative. |
Decay Mode Thresholds |
Start Voltage |
Programmable from 1 to ±1000 V in 1 V increments. |
Start Accuracy |
Within ±1 V of programmed start voltage. |
Stop Voltage |
Programmable from 0 to ±999 V in 1 V increments. |
Stop Accuracy |
Within ±1 V of programmed stop voltage. |
Plate Self-Discharge (unpolarized) |
Less than 12 V/minute. |
Features |
Power On/Off |
A two-position rocker switch. |
Test/Reset Control |
A momentary toggle switch used in conjunction with the Mode Select Switch to program the START and STOP voltages. |
+Decay and -Decay Modes |
Set the plate voltage to a value greater than the programmed start voltage and reset the decay timer to zero. |
Float Mode |
Sets the plate voltage to 0 V ±2 V. |
Voltage Monitor Output |
A BNC providing a low voltage replica of the plate voltage. |
Scale Factor |
1/200th of the plate voltage. |
DC Accuracy |
Better than 0.1% of full scale. |
Offset Voltage |
Less than ±10 mV. |
Output Noise |
Less than 10 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter). |
Output Impedance |
Less than 0.1 ohm. |
Plate Voltage Digital Panel Meter |
3 ½ digit red LED display. |
Range |
0 to ±1100 V. |
Resolution |
1 volt. |
Accuracy |
Better than 0.1% of full scale, ±1 count. |
Decay Time Digital Panel Meter |
4-digit red LED display. |
Range |
0 to 9999 seconds. |
Resolution |
0.1 seconds, from 0 to 999.9 seconds; 1 second, from 1000 to 9999 seconds. (The display will indicate “- - - -” when the decay time exceeds 9999 seconds.) |
Ion Collector Plate |
Standard Option |
Meets ESD Association Standard ANSI/ESD-STM3.1 requirements for: |
Dimensions |
15.3 cm x 15.3 cm square, (6² x 6² square). |
Capacitance |
20 pF ±2 pF. |
Non-standard Option |
Dimensions |
Specify when ordering. |
Capacitance |
Specify when ordering. |
Mode Select |
A three-position toggle switch that selects the +Decay, the -Decay, or the Float mode of operation. This switch is also used in combination with the Test/Reset Control switch to program the start and stop voltages. |
General |
Power Requirements |
Battery Eliminator/Charger |
Optionally available for all nominal line voltages. Contract EMIT or an authorized service organization for more information. NOTE: If line impulses exceed 500 V when using the battery eliminator/charger, the unit may reset and require operator assistance. |
Specifications |
Output Connector |
2.1 mm DC power plug. |
Output Voltage |
12 to 14 V DC. |
Output Current |
1 A. |
Battery Operation |
Rechargeable battery supplied. |
Operating Time |
8 hours with full charge. |
Recharge Time |
3 hours to full charge. |
Other |
Low battery indicator.
Full charge indicator. |
Operating Conditions |
Temperature |
5 °C to 35 °C. |
Relative Humidity |
To 80%, non-condensing. |
Mechanical |
Instrument Dimensions |
83 mm H x 318 mm W x 280 mm D (3.25" H x 12.5" W x 11" D). |
Instrument Weight |
2 kg (4.4 lb). |
Voltage Monitor Connector |
BNC coaxial connector. (3 meter length, maximum.) |
Ground Receptacle |
Banana jack. |
Battery Eliminator/Charger Receptacle |
2.1 mm DC power plug. |
Cable from Instrument to Floating Plate |
Coaxial type. |
Diameter |
4.95 mm (0.195") or 2.6 mm (0.102"). |
Length |
3 m (10 ft), nominal. |
Certification |
EMIT certifies that each Charged Plate Analyzer is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technology or traceable to consensus standards. A Certificate of Calibration accompanies each instrument when it is shipped from the factory. |
Low Voltage Safety Compliance |
EN 61010-1 |
Over-voltage Category |
CAT I: Peripheral level outputs (less than 60 volts). |
Pollution Category |
Degree 1: Operate in environments where no pollution or only dry, non-conductive pollution occurs. |