Similar Items

Comet U5841 - Datalogger for 3 Voltage Inputs 0-10V and 1 Two-state Input

0 reviews | Model: Comet U5841


Voltage datalogger, 4 channels; 3x 0-10V + 1x binary input

  • 3 x voltage input (0 - 10) V
  • 1 x binary input.
  • Connection mode: Split connection block, maximum wire cross section 1.5 mm2 . The maximum cable length is 30 m. It is recommended to use shielded cables.
  • A solution for every need, every budget - economy and premium dataloggers
  • High quality, accurate and stable sensors
  • Built-in battery operated
  • Built-in printer
View Product Details

Your Price: $500.00

Sign-in for EDU Pricing!

In Stock:
  • View Payment Options

Have a question? Ask an expert.


Items in This Series

Comet U5841Comet U0111Comet U0121Comet U0122Comet U0110Comet U0110MComet U0141Comet U0141MComet U0541Comet U0843MComet U3120Comet U3120MComet U3121Comet U3121MComet U3430Comet U3631Comet U3631MComet U4130Comet U4440Comet U4440MComet U6841Comet U6841MComet U7844Comet U7844MComet U8410Comet U0110MsimComet U0121MComet U0121MsimComet U0141MsimComet U0843MsimComet U3120MsimComet U3121MsimComet U3631MsimComet U4440MsimComet U2422Comet U5841MComet U5841MsimComet U6841MsimComet U7844MsimComet U8410MComet U8410MsimComet U0141TMComet U0141TMsim
ProductComet U5841 Voltage datalogger, 4 channels; 3x 0-10V + 1x binary inputComet U0111 Temperature datalogger, 1 channel; 1x Pt1000 inputComet U0121 Temperature datalogger, 2 channels; 2x Pt1000 inputComet U0122 Temperature datalogger, 2 channels; 1x internal sensor + 1x Pt1000 inputComet U0110 Temperature datalogger; internal sensorComet U0110M IoT Wireless Temperature Datalogger with built-in sensor and 2G modemComet U0141 Temperature datalogger, 4 channels; 4x Pt1000 inputComet U0141M IoT Temperature datalogger, 4 channels; 4x Pt1000 inputComet U0541 Temperature datalogger, 4 channels; 2x Pt1000 input + 2x voltage 0-10VComet U0843M IoT Temperature datalogger, 4 channels; 2x Pt1000 input + 2x binary inputComet U3120 Temperature + relative humidity datalogger; internal sensorComet U3120M IoT Temperature + Relative Humidity datalogger, with built-in GSM modem; inte ...Comet U3121 Temperature + relative humidity datalogger; external sensor (T+RH probe is opt ...Comet U3121M IoT Temperature + Relative humidity datalogger; external sensors (T+RH probe ...Comet U3430 Temperature + relative humidity + CO2 datalogger; internal sensorComet U3631 Temperature + relative humidity datalogger; internal sensor + 1x Pt1000 inputComet U3631M Iot Temperature + Relative humidity datalogger with built-in GSM modem; inter ...Comet U4130 Temperature + relative humidity + atmospheric pressure datalogger; internal se ...Comet U4440 Temperature + relative humidity + atmospheric pressure datalogger + CO2; inter ...Comet U4440M IoT Temperature, Relative Humidity, Atmospheric Pressure and CO2 MOBILE datal ...Comet U6841 Current datalogger, 4 channels; 3x 0-20mA + 1 binary inputComet U6841M IoT Current datalogger, 4 channels; 3x 0-20mA + 1 binary inputComet U7844 Pulse and event datalogger, 4 channels; 2x pulse input, 2x binary inputComet U7844M IoT Pulse and event datalogger, 4 channels; 2x pulse input, 2x binary inputComet U8410 U8410 - Datalogger - CO2; internal sensorComet U0110Msim IoT Wireless Temperature Datalogger, with built-in sensor, 2G modem and Fl ...Comet U0121M IoT Temperature datalogger, 2 channels; 2x Pt1000 inputComet U0121Msim IoT Temperature datalogger, 2 channels; 2x Pt1000 inputComet U0141Msim IoT Temperature datalogger, 4 channels; 4x Pt1000 inputComet U0843Msim IoT Temperature datalogger, 4 channels; 2x Pt1000 input + 2x binary inputComet U3120Msim IoT Temperature + Relative Humidity datalogger, with built-in GSM modem; i ...Comet U3121Msim IoT Temperature + Relative humidity datalogger; external sensors (T+RH pro ...Comet U3631Msim Iot Temperature + Relative humidity datalogger with built-in GSM modem; in ...Comet U4440Msim IoT Temperature, Relative Humidity, Atmospheric Pressure and CO2 MOBILE da ...Comet U2422 Atmospheric pressure +CO2 datalogger; external sensor up to 50.000ppm (optiona ...Comet U5841M IoT Current datalogger, 4 channels; 3x 0-10V + 1 binary inputComet U5841Msim IoT Current datalogger, 4 channels; 3x 0-10V + 1 binary inputComet U6841Msim IoT Current datalogger, 4 channels; 3x 0-20mA + 1 binary inputComet U7844Msim IoT Pulse and event datalogger, 4 channels; 2x pulse input, 2x binary inpu ...Comet U8410M IoT CO2 datalogger; internal sensorComet U8410Msim IoT CO2 datalogger; internal sensorComet U0141TM Temperature datalogger, 4 channels; 4x Pt1000 inputComet U0141TMsim Temperature datalogger, 4 channels; 4x Pt1000 input
Price
In Stock
Max Temperature60 C260 C260 C70 C70 C60 C260 C260 C260 C260 C70 C60 C60 C60 C60 C70 C60 C70 C60 C60 C60 C60 C60 C60 C60 C60 C260 C260 C260 C260 C60 C60 C60 C60 C260 C260 C
Min Temperature-20 C (-4 F)-90 C (-130 F)-200 C (-328 F)-30 C (-22 F)-30 C (-22 F)-20 C (-4 F)-200 C (-328 F)-200 C (-328 F)-200 C (-328 F)-200 C (-328 F)-30 C (-22 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-30 F-20 F-30 C (-22 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-200 C (-328 F)-200 C (-328 F)-200 C (-328 F)-200 C (-328 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-20 C (-4 F)-200 C (-328 F)-200 C (-328 F)
Accuracy±10 mV±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °CTEMPERATURE SENSOR: ±0.4 °C TEMPERATURE SENSOR - EXTERNAL PROBE PT1000: ±0.2 °C (-50 to +100 °C); ±0.2 % from reading from +100 to +260 °C; ±0.4 % from reading from -90 to -50 °C ±0.4 °C±0.4 °C±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C±0.2°C; ±0.2 % from reading from +100 to +260 °C ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C±1.5 °C at ambient temperature T <25 °C and RH >30%±1.5 °C at ambient temperature T <25 °C and RH >30%TEMPERATURE SENSOR: ±0.4 °C HUMIDITY SENSOR: ± 1.8 % RH DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 % CO2 SENSOR: ±(50ppm +3% from reading) at 25°C and 1013hPaTEMPERATURE SENSOR: ±0.4 °C TEMPERATURE SENSOR - EXTERNAL PROBE PT1000: ±0.2 °C (-50 to +100 °C); ±0.2 % from reading from +100 to +260 °C; ±0.4 % from reading from -90 to -50 °C HUMIDITY SENSOR: ± 1.8 % RH DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 %TEMPERATURE SENSOR: ±0.4 °C HUMIDITY SENSOR: ± 1.8 % RH DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 %TEMPERATURE SENSOR: ±0.4 °C HUMIDITY SENSOR: ± 1.8 % RH DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 % ATMOSPHERIC PRESSURE SENSOR: ±1.3 hPa at 23 °C from 800 to 1100 hPa±1.5 °C at ambient temperature T <25 °C and RH >30%±1.5 °C at ambient temperature T <25 °C and RH >30%±20 µAAccuracy ±20 µA±(50ppm +3% from reading) at 25°C and 1013hPa ±0.4 °C ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °CTemperature measurement accuracy: ±0.4 °C Humidity measurement accuracy: ± 1.8 % RH Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 %Temperature/Humidity/Dew Point measurement and accuracy: according to the connected probe Digi/ETemperature measurement accuracy: ±0.2 °C (-50 to +100 °C); ±0.2 % from reading from +100 to +260 °C; ±0.4 % from reading from -90 to -50 °C Humidity measurement accuracy: ± 1.8 % RH Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 %Temperature measurement accuracy: ±0.4 °C Humidity measurement accuracy: ± 1.8 % RH Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 % CO2 measurement accuracy: ±(50ppm +3% from reading) at 25°C and 1013hPa Atmospheric pressure measurement accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa±10 mVVoltage measurement accuracy: ±20 µACurrent measurement accuracy: ±20 µA±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C
Compare

Recommended for you

Comet U5841 Accessories


Description

In The Box

Digilent - MCC USB-200

Manufacturer Specs

Tech Specs

Comet U5841 Product Reviews

  • Add to cart

X