Output |
RS232 |
Measured Value |
Temperature + Relative Humidity |
Construction Type |
Compressed Air Humidity up to 2.5MPa |
Design |
Industrial |
Temperature Measuring Range |
-30 to 105 °C |
Relay Output |
Yes |
Two-State Input |
Yes |
Lcd Display |
Yes |
PoE |
No |
Maximum switching voltage, current, power of relay output |
50V, 2A, 60VA |
Audible alarm |
from built-in beeper - switchable |
Relative humidity range |
0 to 100% |
Accuracy of relative humidity measurement |
±2.5% relative humidity from 5 to 95% at 23°C |
Accuracy of temperature output |
±0.4°C from -30 to +100°C
±0.4% from reading over +100°C |
Available temperature units |
degrees Celsius, Fahrenheit |
Dew point temperature range |
-60 to +80 °C |
Accuracy of dew point temperature output (for more details see instruction manual) |
±1.5°C for dew point temperature
+10°C and higher at ambient temperature 25°C |
Accuracy of dew point temperature output |
±2.0°C for dew point temperature 0°C at ambient temperature 25°C |
Accuracy of dew point temperature output |
±3.0°C for dew point temperature -10°C at ambient temperature 25°C |
Accuracy of dew point temperature output |
±6.0°C for dew point temperature -20°C at ambient temperature 25°C |
Accuracy and range of absolute humidity output |
±1.5g/m3 at ambient temperature T < 25°C range 0 to 400 g/m3 |
Accuracy and range of specific humidity output |
±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
Accuracy and range of mixing ratio output |
±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
Accuracy and range of specific enthalpy output |
±3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg |
Signal for binary inputs |
dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated. |
Minimum pulse length at binary input |
500 ms |
Voltage at open contact |
3.3 V |
Low voltage level |
0 to +0.5 V |
High voltage level |
+3.0 to +30V |
Temperature operating range |
-30 to +80°C |
Temperature operating range of LCD display |
readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
Temperature compensation of the humidity sensor |
all temperature range |
Filtering ability of sensor cover |
0.025mm - filter with stainless steel mesh |
Communication protocol |
ModBus RTU and Advantech ADAM compatible protocol |
Communication speed |
110 to 115200 Bd |
IP protection |
IP65 electronics, IP40 sensors |
Power |
9-30Vdc, power consumption approximately 1W |
Mechanical connection of probe |
G1/2 with O-Ring |
Length of the probe cable |
1m, 2m or 4m optionally |
Dimensions |
136 x 159 x 45 mm (W x H x D), probe length 150 mm, probe diameter 18mm |
Weight |
approximately 550g - 1m probe |
Warranty |
3 years |