The Chroma 11021/11021-L are the most cost-effective digital LCR Meters, provide 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. Standard RS232 interface, optional GPIB & Handler interface, high speed and stable measurement capabilities enable the Chroma 11021/11021-L can be used for both component evaluation on the production line and fundamental impedance testing for bench-top applications. Bin-sorting Function The 11021/11021-L provide an 8-bin sorting function with bin count statistics. It is very convenient for magnetic core sorting or capacitor sorting. The bin count statistics can be used for analysis distribution of test results or production quality. HI/GO/LO Comparator The 11021/11021-L meters have a comparator function to judge HI/GO/LOW of capacitance measurement results, and to judge GO/NG of D factor, and an alarming beeper for total GO/NG judgements. Trigger Delay Time For large capacitance measurements in automatic production, an RC (meter output resistance and unknown capacitance) delay time for test signal transients is necessary. The 11021/11021-L provide a trigger delay time for this, and is convenient for automatic equipment timing adjustment. Input Protection Un-discharged devices (generally, capacitors) under test are the most frequent reasons an LCR Meter is destroyed. The 11021/11021-L uses an excellent input protection circuit to prevent it from this kind of damage. Open/Short Zeroing General low-end LCR meters just provide zero offset to substrate stray capacitance, residual resistance or residual inductance only for C, R, L measurement which can not accurately measure Q (quality factor) for L, R measurement and D (dissipation factor) for C measurement. The 11021/11021-L provides full open/short circuit zeroing function. Lower Harmonic-distortion Phase-detection Technology The 11021/11021-L meters use lower harmonic-distortion phase detection technologies to reduce affection of measurement accuracy caused by hysteresis distortion in magnetic component or high dielectric-coefficient capacitor measurement, which is not provided in general low-end LCR meters. General low-end LCR meters use half period integration method as phase detector. The 11021-L is the ideal selection for high frequency coil, core, choke, ect passive components incoming/outgoing material quality inspect and automatic production. The frequency spectrum of half period square wave is shown as figure 1 and 2, which non-ignorable 3rd, 5th order harmonics are included. For non-linear devices under testing, odd-order (3rd, 5th, 7th, etc.) harmonics may occur in measured potential or current signals. Then, this phase-detection method will cause obvious accuracy error because of same low order harmonics are included in both unknown signal and phase-detect signal. The 11021/11021-L uses eight steps sine-wave multiplier as phase detector to reduce low-order harmonics affection to an ignorable level.