General Specification |
Safety and EMC |
CE compliant in accordance with Low Voltage Directive (2014/35/EU) and EMC Directive (2014/30/EU) |
Transmitter |
Operating frequencies |
815 Hz, 8 kHz, 33 kHz, 82 kHz |
Load adjustment |
5 – 20,000 ohm (automatic) |
Output power |
Power levels |
Frequency |
Normal |
High |
815 Hz |
0.2 W |
5 W |
8 kHz |
0.2 W |
5 W |
33 kHz |
0.2 W |
5 W |
82 kHz |
0.2 W |
1 W |
815 Hz + |
0.2 W / |
3 W / |
82 kHz |
0.06 |
0.67W |
Battery type |
Lead-acid battery 12 V, 7 Ah (maintenance-free, leakproof) |
Battery life (depends on load, frequency and power level) |
Continuous operation: Approx. 10 – 20 h
Short-time operation: Approx. 50 – 70 h |
Battery charging cycles |
400 – 1,200 |
Charger |
Power supply |
100 – 240 V, 50/60 Hz, max. 1.5 A |
Charging current |
1,240 mA |
Output Voltage |
DC 14.5 V |
Car charger |
Power supply |
DC 10/15 V |
Charging current |
1.0 A ± 10% |
End-of-charge Voltage |
DC 14.2 V |
Ambient temperature (operational) |
-20°C to +55°C |
Storage temperature |
Lead-acid battery fitted: -20°C to +55°C
Lead-acid battery removed: -40°C to +55°C |
Dimensions (W x H x D) |
Approx. 410 x 160 x 150 mm |
Weight |
Approx. 5 kg |
Degree of protection |
IP54 |
Receiver |
Operating frequencies |
815 Hz, 8 kHz, 33 kHz, 82 kHz, 50/60 Hz, RF/CP |
Operating modes |
Peak method
Pinpoint peak method
Null method
Tracing with right/left indication |
Acoustic signal |
With variable frequency |
Current measurement |
Display of current level of searched cable |
Battery type |
6 x 1.5 V alkaline batteries IEC LR14 |
Battery life |
Continuous operation: Approx. 40 h
Short-time operation: Approx. 82 h |
Signal strength display |
LCD bar display
Digital absolute value (0 – 999) |
Amplification adjustment |
Automatic & manual |
Dynamic amplification |
126 dB |
Depth measurement |
Max. 4.5 m (automatic & 45° method) |
Ambient temperature (operational) |
-20°C to +55°C |
Dimensions (W x H) |
Approx. 770 x 240 mm |
Weight |
Approx. 1.3 kg |
Degree of protection |
IP54 |