Model | Fluke 1587 FC | Megger MIT430/2 | Megger MIT2500 | Megger MIT515 |
---|
Product | Fluke 1587 FC True-RMS Megohmmeter/Insulation Resistance Tester and Multimeter with... | MIT430/2-LG2 (EN ES PT IT) Insulation And Continuity Tester 50/100/250/500/1000V 600 V... | 2.5 kV insulation, continuity, capacitance and result storage and downloading | MIT515-US Insulation Tester 5kV IRT, IR, IR(t), DAR, PI, Battery and line powered to... |
---|
Rating | (10) | (3) | (1) | (1) |
---|
Price | | | | |
---|
In Stock | | | | |
---|
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers |
IR Test Voltage | 1,000 V, 100 V, 250 V, 50 V, 500 V | 1,000 V, 100 V, 250 V, 50 V, 500 V | 1,000 V, 125V, 2,500 V, 250 V, 50 V, 500 V | 1,000 V, 2,500 V, 250 V, 5,000 V, 500 V IR Test Voltage 10 V steps 50 V to 1 kV 25 V steps 1 kV to max. test voltage |
Maximum Insulation Resistance | 2 G Ohms | 200 G Ohms Maximum Insulation Resistance 250V @ 5GΩ 500V @ 10GΩ 1000V @ 20GΩ | 200 G Ohms | 10 T Ohms (10000 G Ohms) |
Automated Test Results | N/A | Dielectric Absorption Ratio, Dielectric Discharge, Leakage Current, Other, Step Voltage | Dielectric Absorption Ratio, Other | Dielectric Absorption Ratio, Dielectric Discharge, Other, Step Voltage Automated Test Results Preconfigured diagnostic tests include Polarization Index (PI) and Dielectric Absorption Ratio (DAR) |
Type | Battery | Battery | Battery | Battery, Line Type Operate from line power when battery fully discharged (charges while operating).
Two and one-half hour full battery charge time (one-half hour charge for one hour testing) significantly increases productivity.
Up to six hours continuous testing (5 kV) on a single battery charge. |
Minimum Insulation Resistance | 0.01 M Ohms (0.00001 G Ohms) | 0.01 Ohms (0.00000000001 G Ohms) | | 10 K Ohms (0.00001 G Ohms) |
Variable Incremental Voltage | No | Yes | Yes Variable Incremental Voltage 50 V to 999 V in 1 V steps, 1.0 KV to 2.5 KV in 10 V steps. | Yes Variable Incremental Voltage 10 V steps 50 V to 1 kV 25 V steps 1 kV to max. test voltage |
Display (Megohmmeter) | Digital | Digital | Digital | Digital Display (Megohmmeter) Digital display, with a responsive analog pointer emulation for evaluating circuit charge and discharge. |
Continuity Test | Yes | Yes | Yes | No |
Live Circuit Voltage Detection | Yes Live Circuit Voltage Detection Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection | Yes Live Circuit Voltage Detection At 50V | Yes | Yes Live Circuit Voltage Detection Dedicated voltmeter function (30 V to 660 V) with frequency measurement allows the user to check for induced voltages |
Power Supply | Battery | Battery | Battery | Battery, Line Powered |
Timer | No | Yes | Yes | Yes |
CAT Rating | IV | IV | IV | IV |
CAT Voltage | 1,000 V, 600 V CAT Voltage CAT III 1000 V and CAT IV 600 V | 600 V | 600 V | 600 V |
Multimeters |
Style | Hand-Held | | | |
Measures AC V | Yes | | | |
Measures DC V | Yes | | | |
Measures AC A | Yes | | | |
Measures DC A | Yes | | | |
True RMS | Yes | | | |
Maximum Voltage AC | 1000 V | | | |
Resolution AC Volts | 0.1 V (100 mV) | | | |
Maximum Voltage DC | 1000 V | | | |
Resolution DC Volts | 0.001 V (1 mV) | | | |
Maximum Current AC | 400 mA (0.4 A) | | | |
Minimum Current AC | 1 mA | | | |
Resolution AC Current | 0.01 mA | | | |
Maximum Current DC | 400 mA (0.4 A) | | | |
Minimum Current DC | 1 mA | | | |
Resolution DC Current | 0.01 mA | | | |
Basic Accuracy V DC | ±(0.09%+2) | | | |
# Digit Display | 3.75 | | | |
Counts | 6000 . | | | |
Backlight | Yes | | | |
Manual/Autoranging | Both | | | |
Decibels | No | | | |
Resistance | Yes | | | |
Frequency | Yes | | | |
Capacitance | Yes | | | |
Temperature | Yes | | | |
Diode Testing | Yes | | | |
Intrinsically Safe | No | | | |
Peak Hold | Yes | | | |
Overload Protector | Yes | | | |
Kelvin 4-Wire Measurement Capability | No | | | |
Wireless Display | No | | | |
Data Hold | Yes | | | |
Low-Pass Filter | Yes | | | |
Test Equipment General Attributes |
Unique Features | Insulation test voltages 50V, 100V, 250V, 500V, 1000V Insulation test: 0.01 MΩ to 2.0 GΩ Auto discharge of capacitive voltage Insulation test smoothing reading Frequency Capacitance Diode test Temperature Min/Max Low pass filter (for work on VSD's) AC/DC Voltage DC millivolts AC/DC milliamps | True RMS voltage measurement – allows accurate voltage measurement on noisy lines
Auto ranging voltage measurement – automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranges
Live circuit warning – automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
Auto fuse warning – warns of fuse failure automatically. No need to test the fuse manually.
Buzzer select button – enable or disable buzzer as required with resistance also displayed on the screen | | Rotary switch operation for easy, intuitive field use.
Field replaceable battery.
Smaller size and lighter weight allows easier transport and use without compromising performance.
High measurement range enables installation testing and long-term trending of higher value apparatus.
Unique dual case design allows for fire-retardant protection while maintaining ruggedness.
High-quality, flexible silicon test leads meet safety regulations of IEC 61010-31:2008 while ensuring measurement accuracy
3 mA short circuit current with unique max power regulations technology ensures maximum transfer whatever the load until selected voltage is reached.
Interference Rejection 1 mA per 250 V up to a maximum of 3 mA
|
Warranty | 3 YEARS | 3 YEARS | 3 YEARS | 2 YEARS Warranty Warranty - Extended warranty over 1 year is conditional on registering the product with Megger within 3 months of purchase. |
Warranty Details | N/A | Years 2 and 3 require free registration of the unit. | | New instruments are covered by a two year warranty from the date of purchase by the user, the second year being conditional on registration of the product on www.megger.com . Any unauthorized prior repair or adjustment will automatically invalidate the warranty. |
Additional Info/Comments | N/A | optional battery charger | | |
Safety Approval | CSA | CE | CE | CE |
Storage | N/A | Internal Memory | | |
IP Rating | IP40 | IP54 | IP54 | IP40, IP65 IP Rating IP65 (lid closed); IP40 (lid open) |
Product Weight | 4.72 LBS | 27.22 OUNCES (1.70 LBS) | | 10 LBS |
Product Height | 7.99 IN | 2.32 IN | 4.50 IN | 12.50 IN |
Product Length | 3.97 IN | 9.00 IN | 12.50 IN | 17.00 IN |
Product Width | 7.96 IN | 4.25 IN | 10.50 IN | 14.00 IN |
Data Logging | No | Yes Data Logging Stores up to 1000 measurements. Data transfer via Bluetooth. | Yes | |
HTS/Schedule B Number | N/A | 9030390000 | 9030390000 | 9030.20.1000 |
ECCN Number | N/A | EAR99 | EAR99 | 3A992 |
Calibration Included | None | Factory Calibration | Factory Calibration | Factory Calibration |
Battery Type | AA Battery Type 4x AA Batteries | AA, NimH | AA, NimH Battery Type 6 AA batteries | Li-ion |
Power Supply Voltage | Battery Powered | Battery Powered | 120V 50/60 Hz | 120V/220V Universal |
Country of Origin | United States | United Kingdom | United Kingdom | United Kingdom |
UPC | 095969262958 | | | |