Model Number |
TBS1022 |
TBS1042 |
TBS1062 |
TBS1064 |
TBS1102 |
TBS1104 |
TBS1152 |
TBS1154 |
Bandwidth 1 |
25 MHz |
40 MHz |
60 MHz |
60 MHz |
100 MHz |
100 MHz |
150 MHz |
150 MHz |
Channels |
2 |
2 |
2 |
4 |
2 |
4 |
2 |
4 |
Sample rate on each channel |
500 MS/s |
500 MS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
Record length |
2.5k points at all time bases |
Vertical system — Analog channels |
Vertical resolution |
8 bits |
Input sensitivity range |
2 mV to 5 V/div on all models with calibrated fine adjustment |
DC gain accuracy |
±3%, from 10 mV/div to 5 V/div |
Maximum input voltage |
300 V RMS CAT II; derated at 20 dB/decade above 100 kHz to 13 V p-p AC at 3 MHz |
Offset range |
2 mV to 200 mV/div: ±1.8 V
>200 mV to 5 V/div: ±45 V |
Bandwidth limit |
20 MHz |
Input coupling |
AC, DC, GND |
Input impedance |
1 MΩ in parallel with 20 pF |
Vertical zoom |
Vertically expand or compress a live or stopped waveform |
Horizontal system — Analog channels |
Time base range |
5 ns to 50 s/div |
Time base accuracy |
50 ppm |
Horizontal zoom |
Horizontally expand or compress a live or stopped waveform |
Input/Output ports |
USB interface |
USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all
PictBridge®-compatible printers |
GPIB interface |
Optional |
Data storage |
Nonvolatile storage |
Reference waveform display |
2.5K point reference waveforms |
Waveform storage without
USB flash drive |
2.5K point |
Maximum USB flash drive size |
64 GB |
Waveform storage with USB
flash drive |
96 or more reference waveforms per 8 MB |
Setups without USB flash
drive |
10 front-panel setups |
Setups with USB flash drive |
4000 or more front-panel setups per 8 MB |
Screen images with USB flash
drive |
128 or more screen images per 8 MB (the number of images depends on file format selected) |
Save All with USB flash drive |
12 or more Save All operations per 8 MB
A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform)
|
Acquisition system |
Acquisition modes |
Peak Detect |
High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/div to
50 s/div |
Sample |
Sample data only |
Average |
Waveform averaged, selectable: 4, 16, 64, 128 |
Single Sequence |
Use the Single Sequence button to capture a single triggered acquisition sequence |
Roll |
At acquisition time base settings of >100 ms/div |
Trigger system |
External trigger input |
Included on all models |
Trigger modes |
Auto, Normal, Single Sequence |
Trigger types |
|
Edge (Rising/Falling) |
Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF
Reject, LF Reject |
Video |
Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) |
Pulse Width (or Glitch) |
Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s |
Trigger source |
Two channel models: CH1, CH2, Ext, Ext/5, AC Line
Four channel models: CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line |
Trigger view |
Displays trigger signal while Trigger View button is depressed. |
Trigger signal frequency readout |
Provides a frequency readout of the trigger source. |
Waveform measurements |
Cursors |
Types |
Amplitude, Time |
Measurements |
ΔT, 1/ΔT, ΔV |
Automatic measurements |
Period, Frequency, +Width, –Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty
Cycle, Phase, and Delay |
Waveform math |
Arithmetic |
Add, Subtract, Multiply |
Math functions |
FFT |
FFT |
Windows: Hanning, Flat Top, Rectangular 2048 sample points |
Sources |
Two channel models: CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2
Four channel models: CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2, CH3 – CH4, CH4 – CH3, CH3 + CH4, CH3 × CH4 |
Autoset |
Autoset menu |
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset |
Square wave |
Single Cycle, Multicycle, Rising or Falling Edge |
Sine wave |
Single Cycle, Multicycle, FFT Spectrum |
Video (NTSC, PAL, SECAM) |
Field: All, Odd, or Even Line: All or Selectable Line Number |
Autorange |
|
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal
exhibits large changes. |
Display system |
Interpolation |
Sin (x)/x |
Waveform styles |
Dots, vectors |
Persistence |
Off, 1 s, 2 s, 5 s, infinite |
Format |
YT and XY |
Physical characteristics |
Dimensions |
mm |
in. |
|
|
158.0 |
6.22 |
|
|
326.3 |
12.85 |
|
|
124.2 |
4.89 |
Shipping dimensions |
mm |
in. |
|
|
266.7 |
10.5 |
|
|
476.2 |
18.75 |
|
|
228.6 |
9.0 |
Weight |
kg |
lb. |
|
|
2.0 |
4.4 |
|
|
2.2 |
4.9 |
RM2000B rackmount |
mm |
in |
|
|
482.6 |
19.0 |
|
|
177.8 |
7.0 |
|
|
108.0 |
4.25 |
Environmental |
|
|
|
Temperature |
|
Operating |
0 to +50 ºC |
Nonoperating |
–40 to +71 ºC |
Humidity |
|
|
|
Operating and nonoperating |
Up to 85% RH at or below +40 ºC
Up to 45% RH up to +50 ºC
|
|
Altitude |
Operating and nonoperating |
Up to 3,000 m (9,843 ft.) |
Regulatory |
|
|
|
Electromagnetic compatibility |
Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework |
Safety |
UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001 |