Rigol Probes - Overview Specification |
Passive high resistance probe |
RP2200 |
1:1 or 10:1 |
1x: DC...7 MHz
10x: DC...150 MHz |
1x: 1 MΩhm ±2%
10x: 10 MΩhm ±2% |
1x: CAT II 150 VAC
10x: CAT II 300 VAC |
All Rigol scopes |
Small signal test (1x), general purpose test |
RP3300A |
10:1 |
10x: DC...350 MHz |
10x: 10 MΩhm ±2% |
10x: CAT II 300 VAC |
All Rigol scopes |
Small signal test (1x), general purpose test |
RP3500A |
10:1 |
DC...500 MHz |
10 MΩhm ±2% |
CAT II 300 VAC |
All Rigol scopes |
General purpose test |
RP5600A |
10:1 |
DC...600 MHz |
10 MΩhm ±2% |
CAT II 300 VAC |
DS4000 series*, DS6000 series |
General purpose test |
Passive low resistance probe |
RP6150A |
10:1 |
DC...1.5 GHz |
500 Ωhm
±10 Ωhm |
CAT I 7 VAC |
DS4000 series*, DS6000 series |
High frequency signal ended small signal test |
Passive high voltage probe |
RP1300H |
100:1 |
DC...300 MHz |
100 MΩhm |
CAT I 2000 V(DC+AC)
CAT II 1500 V(DC+AC) |
All Rigol scopes |
High voltage test |
RP1010H |
1000:1 |
DC...40 MHz |
100 MΩhm, 3 pF
±0.5 pF |
0...10 kVDC, AC pulse
≤20 kVpp/sine =7 kVRMS |
All Rigol scopes |
High voltage test |
RP1018H |
1000:1 |
DC....150 MHz |
200 MΩhm,
1.5 pF |
CAT II 18 kV(DC+AC)
CAT III 12 kV(ACRMS) |
All Rigol scopes |
High voltage test |
Active differential probe |
RP7150 |
10:1 |
DC...1500 MHz |
Differential 50 kΩhm ±2%
Single-ended 25 kΩhm ±2% |
~30 Vp; CAT I |
DS4000 series*, DS6000 series |
Differential/single-ended high frequency signal test |
RP7080 |
10:1 |
DC...800 MHz |
Differential 50 kΩhm ±2%
Single-ended 24 kΩhm ±2% |
~30 Vp; CAT I |
DS4000 series*, DS6000 series |
Differential/single-ended high frequency signal test |
Active single-ended probe |
RP7150S |
10:1 |
DC...1500 MHz |
100 kΩhm ±1% |
~30 Vp; CAT I |
DS4000 series*, DS6000 series |
Single-ended high frequency signal test |
RP7080S |
10:1 |
DC...800 MHz |
100 kΩhm ±1% |
~30 Vp; CAT I |
DS4000 series*, DS6000 series |
Single-ended high frequency signal test |
High voltage differential |
RP1025D |
x20, x50, x200 |
25 MHz |
Differential 4 MΩhm/1.2 pF
Single-ended 2 MΩhm/2.3 pF |
x20: =140 Vpp, (45 Vrms or DC)
x50: =350 Vpp, (110 Vrms or DC)
x200: =1400 Vpp, (450 Vrms or DC) |
All Rigol scopes |
High voltage differential/single-ended signal test |
RP1050D |
x100, x200, x1000 |
50 MHz |
Differential 100 MΩhm/1.2 pF
Single-ended 50 MΩhm/2.3 pF |
x100: =700 Vpp, (230 Vrms or DC
x200: =1400 Vpp, (460 Vrms or DC)
x500: =3500 Vpp, (1140 Vrms or DC)
x1000: =7000 Vpp, (2300 Vrms or DC) |
All Rigol scopes |
High voltage differential/single-ended signal test |
RP1100D |
x100, x200, x1000 |
100 MHz |
Differential 100 MΩhm/1.2 pF
Single-ended 50 MΩhm/2.3 pF |
x100: =700 Vpp, (230 Vrms or DC)
x200: =1400 Vpp, (460 Vrms or DC)
x500: =3500 Vpp, (1140 Vrms or DC)
x1000: =7000 Vpp, (2300 Vrms or DC) |
All Rigol scopes |
High voltage differential/single-ended signal test |
* incl. MSO4000 |