DC Voltage | Ranges: 2V, 20V, 200V, 1000V Best Resolutions: 10 µV (Slow), 100 µV (Med), 1mV (Fast) Accuracy: ± (0.05% + 3D) Input impedance: 10MW Overload protection: 1000V | AC Volts | Ranges: 2V, 20V, 200V, 1000V Best Resolutions: 100 µV (Slow and Med), 1mV (Fast) Accuracy: ± (0.5% + 5D) 45Hz to 450Hz Overload Protection: 1000V Crest Factor: 3:1 | DC Current | Ranges: 200µA, 200mA, 10A Best Resolutions: 200µA: 1nA (Slow), 10nA (Med),100nA (Fast) 200mA: 1µA (Slow), 10µ (Med), 100µA (Fast) 10A: 100µA (Slow), 1mA (Med), 10mA (Fast) Accuracy: ± (0.1% + 5D) Max burden: 200mV Overload protection: 0.5A/250V and 10/250V fuse | AC Current (Best Resolution) | 200 µA: 10 nA (Slow and Med), 100nA (Fast) 200mA: 1µA (Slow), 10µA (Med), 100µA (Fast) 10A: 100µA (Slow), 1mA (Med), 10mA (Fast) Accuracy: ± (0.5% + 5D), Max burden: 200mV Overload protection: 0.5A/250V and10A/250V fuse | Resistance | Ranges: 200W W2KW, 200KW, 2MW, 10MW Best Resolutions: 1mW (Slow), 10mW (Med), 100mW (Fast) Accuracy: ±(0.05% + 5D) Overload Protection: 250V or AC RMS | Frequency | Ranges: 200Hz, 2KHz, 20KHz, 200KHz Best Resolutions: 1mHz(Slow), 10mHz (Med), 100mHz (Fast) Accuracy: ± (0.05% + 2D) Overload protection: 250V DC or AC RMS | Diode | Range: 2V Test current: Approximately 1.0mA Test Volts: Approximately 3 Volts | Continuity | Buzzer will sound at 100W or less | Interface | RS-232, GPIB optional Connector: 9 Pin din Baud Rate: 1200, 2400, 4800 or 9600 bps | |