PMK PHV 1000 High Z-Probe 1 kV AC, Ratio: X100 Bandwidth: 400 MHz, 2 Meter Cable

Click image to enlarge
PMK PHV 1000
|
|
PHV 1000 and PHV 1000-RO Series Probes
- Multipurpose (Bench & Field Use)
- High Quality
- Economical
- Measure voltage to 5 kV peak impulse
- System Bandwidth to 400 MHz
- Measurement Applications:
- Power Supplies
- Motor Drives
- Power Semiconductors
- The PHV 1000 is our lowest cost probe for measuring voltages in the kV range
- The PHV 1000-RO is our universal probe for field service
- 1 Year Warranty (materials & workmanship)
Features:
- High Input Impedance (X10 & X100 attenuation ranges)
- Interchangeable Probe Tip
- System Rise Time <0.9 nsec
- Single High Frequency Adjustment
- DC Fine adjustment
- Coaxial Design
- HV Reed Switch (PHS: X10/X100 attenuation range)
- Accessory Pack Included Includes: 1 each
- Spring Contact Tip, 0.8 mm (mounted in probe)
- Rigid Tip, 0.8 mm
- Spring Hook, Red
- Insulating Cap, Black
- IC Insulating Cap, Black
- 9 Inch Ground Lead
- Trimmer Tool
- Available with readout (PHV 1000)
- Available with additional cable lengths
|
Description
| PHV 1000, Probe 1, 5 kV AC eff CAT II 1, 2 Meter Cable - Ratio: X100 - System Bandwidth: 400 MHz |
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| PHV 1000 |
Probe, 1 KV ACrms, 2.0 m - Ratio: X100 - System Bandwidth: 400 MHz |
| $86.94 |  |
|
| PHV 1000 RO |
Probe, 1 KV ACrms, 2.0 m, Readout Installed - Ratio: X100 - System Bandwidth: 400 MHz |
| $99.54 |  |
|
Specifications
| Model |
Order-No. |
Attenuation |
Input Impedance |
Input Coupling of the Measuring Instrument |
System Bandwidth |
Risetime |
| (-3dB) |
(10% - 90%) |
| PHV 1000-RO |
860-622-A02 |
100:1 |
50 MΩ 7.5 pF |
1 MΩ AC/DC |
400 MHz |
0.9 nsec |
PHV 1000 C-RO in hard case |
86C-622-A02 |
100:1 |
50 MΩ 7.5 pF |
1 MΩ AC/DC |
400 MHz |
0.9 nsec |
| PHV 1000-3-RO |
860-623-A02 |
100:1 |
50 MΩ 7.5 pF |
1 MΩ AC/DC |
250 MHz |
1.4 nsec |
PHV 1000-3 C-RO in hard case |
86C-623-A02 |
100:1 |
50 MΩ 7.5 pF |
1 MΩ AC/DC |
250 MHz |
1.4 nsec |
| Model |
Order-No. |
Compensation Range |
Rated Voltage |
Safety Standard |
Cable Length |
| Measurment Category I |
Measurment Category II |
(IEC / EN) |
| PHV 1000-RO |
860-622-A02 |
10 ... 50 pF |
1000 V AC rms or DC 4000 V transient overvoltage |
1000 V CAT II |
61010-031 |
2 m |
PHV 1000 C-RO in hard case |
86C-622-A02 |
10 ... 50 pF |
1000 V AC rms or DC 4000 V transient overvoltage |
1000 V CAT II |
61010-031 |
2 m |
| PHV 1000-3-RO |
860-623-A02 |
10 ... 50 pF |
1000 V AC rms or DC 4000 V transient overvoltage |
1000 V CAT II |
61010-031 |
3 m |
PHV 1000-3 C-RO in hard case |
86C-623-A02 |
10 ... 50 pF |
1000 V AC rms or DC 4000 V transient overvoltage |
1000 V CAT II |
61010-031 |