Megger Insulation Test Equipment (10, 15, & 30 kV)
Available Models (10, 15, & 30 kV) | Selection Guide (All) | Discontinued (10 & 15 kV)
| Model |
Description or Specification |
 MIT1020/2 |
MIT1020/2 10-kV Insulation Resistance Tester Version 2 This 10 kV insulation resistance tester from Megger is designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. IEEE 43-2000 recommends the use of 10 kV for motor windings rated above 12 kV and the Megger MIT1020 facilitates this. |
 210415 |
Megger 210415 15kV Megohmmeter The Megger 15-kV Megohm-meter is a high-voltage, line operated instrument. It provides a continuously variable test voltage for highly sensitive insulation resistance measurements of all types for electrical equipment and power cables. |
 MIT30 |
30-kV High Voltage Insulation Tester
High Voltage DC Insulation Testers measure leakage current while applying a dc voltage at or above the insulation system’s operating level. This measurement aids in determining the insulation system’s ability to withstand overvoltages such as lightning strikes and switching surges. |
Selection Guide
| Model |
Sensitivity |
Voltage (min-max) |
Apparatus |
Testing Requirements |
| 1000 MΩ |
250 - 1 kV |
Domestic and industrial systems, site maintenance and service departments, transformers, motors, generators, switchgear, panel building, domestic appliances, power tools etc., fixed electrical wiring systems |
|
| 999 MΩ |
250 - 500 V |
Domestic, Commercial and industrial wiring, Panels, motors, generators, switchgear, power tools, street lighting |
Standard voltage testing with moderate sensitivity required; rugged and physically demanding test environments; simplified operation |
| 250 - 1 kV |
| 20 GΩ |
250V, 500V, 1000V |
Domestic, industrial service, and maintenance Manufacturing, production testing, Electrical installation, Panel building, Railway and other transportation |
|
| 100 GΩ |
50V, 100V, 250V, 500V, 1000V |
| 200 GΩ |
2 - 20 GΩ Depending on voltage |
10V to 100V variable (1V increments) |
| 100 GΩ |
50V, 100V |
Domestic, industrial service, and maintenance Manufacturing, production testing, Electrical installation, Panel building, Railway and other transportation, Telecommunications industry |
|
| 200 GΩ |
50V, 100V, 250V, 500V, 1000V |
| 20 GΩ |
500 - 5 kV |
Lower quality transformers, motors, capacitors, power cables |
Higher Voltage required for testing but sensitivity less important |
| 100 GΩ |
5 kV |
For highly sensitive insulation-resistance measurements of all types of electrical equipment and power cable. |
|
| 300 GΩ |
15 kV |
| 20 GΩ |
100 - 1 kV |
15-kV and below power cable, small motors, appliances, power tools |
Standard voltage testing with higher sensitivity requirements, broad voltage range |
| 2 GΩ |
100 - 1 kV |
15-kV and below power cable, small motors, appliances, power tools |
Standard voltage testing with lower sensitivity requirements, broad voltage range |
| 15 TΩ |
500 - 5 kV |
Large transformers, large motors, switchgear, large capacitors, high-voltage cabling |
High level sensitivity requirements, enhanced troubleshooting for continuity |
| 50 - 5 kV |
Large transformers, large motors, switchgear, large capacitors |
Highest level sensitivity for long term preventative maintenance testing, catastrophic change testing |
| 35 TΩ |
50 - 10 kV |
Specifically, rotating machinery rated > 12 kV; generally, any heavy equipment with high-voltage ratings |
Maintenance of high-voltage equipment; IEEE43-2000 compliant; Step-voltage and PI testing |
Discontinued
| |
Discontinued |
Replaced by |
 |
MEG10-01 Analog/Digital 5 kV Megger; 500, 1000, 2500, 5000, 10,000 V; 500 Gohms Digital |
Megger MIT1020/2 |
 |
MIT1020 Analog/Digital 10 kV Megger; 500, 1000, 2500, 5000, 10,000 V; 35 Tohms |
Megger MIT1020/2 |
|