Iwatsu SS-7802A Analog Oscilloscope

Click image to enlarge
|
Quick auto setup (CH1, CH2) |

SS-7847A/7840A/7830A/7821A/7811A/7810A
Click image to enlarge
|
| Input signals are quickly shown in the optimum range. |
Frequency counter |

All models:
6-digit: SS-7847A/7840A/7830A,
5-digit: SS-7821A/7811A/7805A/7804A/7802A
Click image to enlarge
|
| The built-in 6/5-digit counter is accurate within a range of ±0.0025% / ±0.01% and can measure frequencies between 2Hz and 400MHz. Also shows the trigger signal frequencies. |
DC offset function (CH1, CH2) |

SS-7847A/7840A/7830A
Click image to enlarge
|
| Convenient when you need to observe a signal with very small amplitude superimposed over a signal with large amplitude.
Especially useful when observing high-frequency noise superimposed over video signals or ripple of high-voltage DC power supply. |
TV/HDTV triggering |

TV: All models, HDTV: SS-7847A/7840A/7830A/7821A/7811A/7810A
Click image to enlarge
| TV-V field (EVEN, ODD, BOTH) and line selection is possible for HDTV, NTSC, PAL/SECAM, meeting the needs of engineers who want to observe HDTV signals without any attenuation (even as low as 0.1 dB). |
Pedestal clamp function (CH1, CH2) for TV signals |
 SS-7847A/7840A/7830A
Click image to enlarge
|
| The amplitude of video signals varies dynamically depending on the picture. This function ensures stable observation. |
CH2 skew adjust |

SS-7847A/7840A/7830A
Click image to enlarge
|
| The delay time of CH2 in response to CH1 can be adjusted with a range of 1 ns. Therefore, accurate measurement is possible by compensating for the delay time difference between the probes. |
DC - 470MHz/400MHz/300MHz (all channels) high-sensitivity of 2 mV/div (CH1, CH2) |
| DC - 470MHz (SS-7847A)/DC - 400MHz (SS-7840A)/DC - 300MHz (SS-7830A) for all channels. CH1 and CH2 have max. sensitivity of 2 mV/div, ensuring extremely high-quality waveforms. |
IWATSU-developed bright, sharp CRT (Japan made) |
SS-7847A/7840A/7830A/7821A/7811A/ 7810A/7805A/7804A Features superlative brightness and sharpness that even allows you to easily observe signals with slow repetition and a high-speed rise time transition. |
IWATSU-developed preamp IC for improved signal stability |
All models To increase signal stability, a preamp circuit has been provided for the IC. |
Panel settings save/recall function |
All models To increase signal stability, a preamp circuit has been provided for the IC. |
Event trigger |
All models To increase signal stability, a preamp circuit has been provided for the IC. |
Probe power supply provided as standard |
All models To increase signal stability, a preamp circuit has been provided for the IC. |
|
|
Features:
- DDC - 20MHz, 2 CH + ext. trigger input, 2 traces
- Cursor measurement function
- ±2% accuracy for vertical axis sensitivity
- Full TV triggering with TV line selection capability
- 5-digit frequency counter
- Single-sweep function
|
Eye-patterns in optical disc manufacturing process |
| |
Click images to enlarge |
|
When evaluating optical discs such as Blu-ray Discs, HD-DVDs, CDs or DVDs, eye patterns need to be observed.
With this analog oscilloscope, accurate observation of the eye patterns of high-speed and high-density media is easily possible.
* Blu-ray Disc signal eye pattern waveform |
Video head frequency modulation signals |
| |
Click images to enlarge |
|
Input and output signals to/from video heads are frequency modulation waveforms.
The voltage of recorded or read-out signals to/from the video heads is specified. To observe these FM signals, an analog oscilloscope is indispensable.
* VHS deck head signal waveform |
ATM 155 Mbps signal eye patterns |
| |
Click images to enlarge |
|
The standard transmission rate for most networked communication systems is 155 Mbps (STM-1).
The amount of jitter can be estimated by observing the signal waveform with the eye pattern and following the pulse mask standard.
* 155 Mbps signal eye pattern waveform measured with SS-7847A (DC - 470MHz) |
Full TV triggering |
| |
Click images to enlarge |
|
| TV-V (ODD field, EVEN field, BOTH fields) and TV-H are available.
Line number selection in TV-V mode is useful for detailed evaluation of video signals.
HDTV can be selected, as well as NTSC or PAL/SECAM (except for SS-7805A/7804A/7802A) |
|
Switching power supply measurement |
|
Click images to enlarge |
|
| A switching power supply unit with a higher harmonics measure switches the voltage of a commercial power supply at high speed.
In terms of circuit operation, switching stops at the zero cross of the AC power supply. To observe this condition,
an analog oscilloscope is required. Analog oscilloscopes are also superior when simultaneously observing voltage and current waveforms.
In addition, when magnifying a switching waveform for observation on an analog oscilloscope, no complicated operations are required to trigger the waveform. |
|
Description
| Convinent, Easy-To-Use, and High Performance |
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| SS-7802A |
20MHz, 2CH ANALOG OSCILLOSCOPE CE |
$1257.80 |
| $1092.30 |  |
|
Specifications
|
|
SS-7821A
|
SS-7811/7810A
|
SS-7805A
|
SS-7804A
|
SS-7802A
|
| Display |
| CRT |
6-inch rectangular, internal graticule (8 x 10 div, with scale illumination) - Japan made |
6-inch rectangular, internal graticule (8 x 10 div) |
| Accelerating voltage |
Approx. 16 kV |
2 kV |
| Vertical deflection system |
| Mode |
CH1, CH2, CH3, ADD, ALT, CHOP |
CH1, CH2, ADD, ALT, CHOP |
| Frequency bandwidth |
|
| 5 mV/div - 5 V/div |
DC - 200MHz |
DC - 100MHz |
DC - 50MHz |
DC - 40MHz |
DC - 20MHz |
| 2 mV/div |
DC - 50MHz |
DC - 50MHz |
DC - 20MHz |
DC - 20MHz |
DC - 10MHz |
| Sensitivity (CH1, CH2) |
2 mV/div - 5 V/div 11-step (1-2-5), 2 mV - 12.5 V/div(with vernier) |
| Accuracy |
±2% |
| Bandwidth limiter |
20MHz Not provided |
| Rise time (Calculated from freq. bandwidth x rise time = 0.35) |
1.75 nsec |
3.5 nsec |
7.0 nsec |
8.75 nsec |
17.5 nsec |
| Signal delay |
Available Not provided |
| Input coupling |
AC, DC, GND (The cut-off freq. Is 4Hz with AC coupl.) |
| Input RC - direct |
1 Mω ±1.5% // 20 pF ±2 pF |
1 Mω ±1.5% // 25 pF±2 pF |
| Max. input |
1 Mω input : 400 V (DC + AC peak), with 10:1 probe : 600 V (DC + AC peak) |
| Polarity switching |
Possible only for CH2 |
| Probe sensor |
1:1, 1:10, 1:100 detection possible |
| Sensitivity (CH3) |
50 mV/div, 100 mV/div, 500 mV/div, ±2% – |
– |
| Input coupling |
AC, DC |
– |
| Triggering |
| A triggering |
|
| Source |
VERT, CH1, CH2, CH3, LINE |
VERT, CH1, CH2, EXT, LINE |
| Coupling |
AC, DC, HF-REJ, LF-REJ |
| Level |
|
| DC - 5MHz |
0.4 div |
0.4 div |
0.4 div |
0.4 div |
0.4 div |
| 5MHz - 10MHz |
0.4 div |
0.4 div |
1.0 div |
1.0 div |
1.0 div |
| 10MHz - 40MHz |
1.0 div |
1.0 div |
1.0 div |
1.0 div |
1.0 div (-20MHz) |
| 40MHz - 50MHz |
1.0 div |
1.0 div |
1.0 div |
– |
| 50MHz - 100MHz |
1.0 div |
1.0 div |
– |
| 100MHz - 200MHz |
1.5 div |
– |
– |
| B triggering |
|
Not provided |
| Source |
CH1, CH2, CH3, LINE |
– |
| Coupling |
AC, DC, HF-REJ, LF-REJ |
– |
| TV triggering |
NTSC, PAL/SECAM, HDTV |
NTSC, PAL/SECAM |
| Trigger mode |
TV-V (ODD, EVEN, BOTH) line number selectable, TV-H |
| EXT triggering input |
| Level |
| DC - 5MHz |
– |
80 mV |
80 mV |
80 mV |
| 5MHz - 20MHz |
– |
200 mV |
200 mV |
200 mV |
| 20MHz - 40MHz |
– |
– |
200 mV |
– |
| 20MHz - 50MHz |
– |
200 mV |
– |
– |
| Max. input voltage |
– |
1 Mω : 400 V (DC + AC peak) |
| X-Y |
| X-axis |
CH1 |
| Sensitivity |
Same as CH1 |
| Accuracy |
±3% |
| Bandwidth |
DC - 2MHz |
DC - 1MHz |
| Y-axis |
|
| Operating channel |
CH1, CH2, CH3, ADD CH1, CH2 |
CH1, CH2 |
| Horizontal deflection system |
| Horizontal display |
A, ALT, B, X-Y |
A, X-Y |
| Mode |
AUTO, NORM, SINGLE |
| A sweep time |
|
| Fastest range with mag. |
1 nsec/div |
2 nsec/div |
10 nsec/div |
10 nsec/div |
20 nsec/div |
| Slowest range |
500 msec/div |
| B sweep time |
- |
Not provided |
| Fastest range with mag. |
1 nsec/div |
2 nsec/div |
– |
| Slowest range |
5 msec/div |
|
| Accuracy |
A/B ±2% |
| Delay |
Triggered delay CH1, CH2, CH3 Continuous delay: RUNS AFTER |
– |
| Delay jitters |
1/20,000 |
– |
| Magnifier |
10 times |
| Hold-off time |
Variable (up to sweep length or longer) |
| Auto setup |
V/H position, V/H range,trigger |
Not provided |
| Input channel |
CH1, CH2 |
– |
| Frequency response |
50Hz - 50MHz – |
– |
| CH2 signal output |
DC - 100MHz |
DC - 100MHz |
DC - 20MHz |
DC - 20MHz |
DC - 10MHz |
| Calibrator |
Square-wave, 1kHz±0.1%, 0.6 Vp-p±1% |
| CRT read-out |
|
| Read-out |
Attenuator range, ADD UNCAL, AC/DC/GND, vertical mode, CH2 polarity, A/B sweep range, x10 MAG, UNCAL, horizontal display mode, hold-off Trigger coupling, trigger source, trigger slope, TV -field, TV-line, TV-system |
| Cursor measurement |
ΔV (voltage measurement), Δt (time measurement), 1/Δt(division calculation by Δt) |
| Frequency counter |
5-digit, 0.01% |
| Frequency range |
2Hz - 200MHz, reciprocal |
2Hz - 100MHz, reciprocal |
2Hz -50MHz, reciprocal |
2Hz - 40MHz, reciprocal |
2Hz - 20MHz, reciprocal |
| Save and recall |
Up to 32-setup (only for SS-7821A/SS-7811A) |
Not provided |
| Power off set-up |
Panel setting before switch is powered off |
| Back-up |
Battery back-up (approx. 30,000 hr) |
| Power supply |
AC 90 V - 132 V/180 V - 250 V, 50Hz - 400Hz, max. 110 VA |
AC 100 V/110 V - 120 V/220 V/ |
230 V - 240 V, 50Hz - 60Hz |
| Dimensions and weight |
272W x 152H x 390L mm, approx. 7.5 kg |
272W x 152H x 390L mm, approx. 8.5 kg |
| Environment conditions |
| Operating |
0°C - +40°C, 90% RH (40°C) |
| Performance guaranteed |
+10°C - +35°C |
| Standard accessories |
Power cable (x 1), probe (x2), fuse (x2), panel cover (x1), operation manual (x 1) |
Power cable (x 1),probe (x 2), panel cover (x 1),operation manual (x 1) |
|