company logo IET Labs Resistance Decade Boxes
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



IET Labs Resistance Decade Boxes


Model Description or Specification
RS Series
Type: General / Field grade
Basic Accuracy: 0.1% (or better) to 1%
Range: .001Ω -100 MΩ
Max. Resolution: 10 mΩ
Features: Economical, toolbox size
RCS Series
Type: Field grade Resistance and Capacitance Box
Basic Accuracy: 0.1% (or better) to 1%
Range: .001Ω -100 MΩ
Max. Resolution: 10 mΩ
Features: Consists of an RS Resistance Box, and a CS Capacitance Box
OhmSource
Type: Elec-Res Box
Basic Accuracy: 0.10%
Range: 0.5 Ω - 24 MΩ
Max. Resolution: 10 mΩ
Features: Economical, microprocessor controlled
GenRad 1433
Type: High accuracy
Basic Accuracy: 0.01%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade
HARS-X
Type: High accuracy
Basic Accuracy: 0.01%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade, high accuracy, high stability, low zero resistance, low temperature coefficient, suitable for RTD simulation.
HARS-Q/A/B
Type: High accuracy
Basic Accuracy: 0.02% - 0.05% - 0.1%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade, high accuracy, high stability, low zero resistance, low temperature coefficient, suitable for RTD simulation.
HARS-L
Type: Lab/cal grade
Basic Accuracy: 25 ppm + 0.5 mΩ absolute
Range: 10 mΩ-120 MΩ
Max. Resolution: 1 mΩ, 20 uΩ
Features: Laboratory grade, high accuracy, high stability, low zero resistance, low temperature coefficient, suitable for RTD simulation.
HARS-LX
Type: Lab/cal grade
Basic Accuracy: 20 ppm + 0.5 mΩ absolute
Range: 10 mΩ -120 MΩ
Max. Resolution: 1 mΩ, 20 uΩ
Features: Laboratory grade, high accuracy, high stability, low zero resistance, low temperature coefficient, suitable for RTD simulation.
HRRS
Type: High resistance High voltage
Basic Accuracy: 0.01% - 1%
Range: 0 - 10 TΩ
Max. Resolution: 10 Ω
Features: High resistance
HRRS-5kV
Type: High power
Basic Accuracy: 0.01% - 1%
Range: 0 - 10 TΩ
Max. Resolution: 10 Ω
Features: High resistance to 5 kV
HPRS
Type: High power
Basic Accuracy: 0.5% - 1%
Range: 0 - 10 MΩ
Max. Resolution: 1 mΩ
Features: High power; 25 W/step; 250 W max.
PRS
Type: Programmable
Basic Accuracy: 0.01% - 1%
Range: 0 - 100 MΩ
Max. Resolution: 1 mΩ
Features: IEEE-488 or RS-232
HATS-LR
Type: Transfer standard
Basic Accuracy: 1 ppm transfer
Range: 1 Ohms - 100 kΩ/step
Max. Resolution: 1 Ω
Features: High accuracy transfer standard
HATS-Y
Type: Transfer standard
Basic Accuracy: 2ppm transfer
Range: 100 kΩ - 10 MΩ/step
Max. Resolution: 100 kΩ
Features: High accuracy transfer standard
KVD-700
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.1 ppm linearity
Range: 0 to 1100 V
Max. Resolution: 0.1 ppm
Features: Highly accurate for bridge applications to measure and calibrate voltages, resistance, etc.
KVD-600
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.5 ppm linearity
Range: 0 to 1100 V
Max. Resolution: 0.1 ppm
Features: Highly accurate for bridge applications to measure and calibrate voltages, resistance, etc.
KVD-500
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.05% to 1%
Range: 1 Ω - 100 kΩ
Max. Resolution: 1 ppm
Features: General purpose; economical; thumbwheel switches.
DP-500
Type: True digital pot
Basic Accuracy: 0.05% - 1%
Range: 0 - 50 MΩ
Max. Resolution: 1 ppm
Features: Suitable as component




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on IET










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.