| Measurement function | Feature | Version |
Memory recorder | High-speed data saving | Basic version |
Recorder | Real time recording |
RMS recorder | For commercial power supplies |
Recorder & Memory | Real time recording & Highspeed data saving | Advanced version |
FFT | Frequency analysis |
Number of channels (maximum) | 8 analog channels + 16 logic channels (The logic channels are standard equipment for the 8835-01, common ground with main unit) |
Memory capacity | 4 M words When 1 channel is in use: 12 bits 4 M words/channel When 2 channels are in use: 12 bits 2 M words /channel When 4 channels are in use: 12 bits 1 M words /channel When 8 channels are in use: 12 bits 500 K words /channel |
Maximum sampling period | 1 s (all channels simultaneously)(Maximum sampling speed: 1 MS/s, all channels simultaneously) |
Time axis accuracy | 0.01% (difference between grid and actual time) |
Input method | Plug-in analog units |
External control connections | External trigger input, trigger output, GO/NG output, external start/stop, print input |
Time measurement functions | Auto calendar with automatic leap year, 24 hour clock |
Backup battery and lifetime | Used for clock and to preserve settings, approx. 10 years (reference value at 25) To preserve waveforms, approximately one hour after shutting down MEMORY HiCORDER power (requires a minimum of two minutes upon power up) (reference value at 25) |
Operational ranges for temperature and humidity | Temperature: 5 to 40°C (41 to 104°F) Relative humidity: 35% to 80%RH (with no condensation) |
Operating place | Max. 2000 m (6562 feet) height, indoors |
Temperature and humidity ranges for assured accuracy Guaranteed accuracy period | Temperature: 23°C 5°C (73 9°F) Relative humidity: 35% to 80%RH (with no condensation) For 1 year |
Temperature and humidity ranges for storage | Temperature: -10 to 50°C (14 to 122°F) Relative humidity: 20% to 90%RH (with no condensation) |
Insulation resistance | At least 100 M/500 VDC |
Dielectric strength | One minute at 1.35 kVAC between the main unit and the power supply One minute at 3.7 kVAC between the input units and the main unit, and between the input units (see Section 15.2 of the 8835-01 Instruction Manual.) |
Power supply | Rated power voltage 100 to 120 VAC, 200 to 240 VAC (auto-switching) Rated power frequency 50/60 Hz 10 to 28 VDC (the optional DC power adapter is used) (Voltage fluctuations of 10% from the rated supply voltage are taken into account.) |
Maximum rated power | AC: 150 VA (55 W) (when 2 8936 ANALOG UNITs are installed) DC: 80 VA (80 W) (when 2 8936 ANALOG UNITs are installed) AC: 230 VA (95 W) (when 2 8940 F/V UNITs are installed) DC: 80 VA (80 W) (when 2 8940 F/V UNITs are installed and 2 ch current testing is ON) |
Dimensions | Approx. 285W x 220H x 132D mm (11.22"W x 8.66"H x 5.20"D) (excluding projections) |
Mass | Approx. 4.5 kg (158.73 oz.) |
Standards applying | EMC EN61326 ClassA EN61000-3-2 EN61000-3-3 Safety EN61010 Pollution Degree 2, Measurement Category II (anticipated transient overvoltage: 4000 V) |