Features:
- The GL800 has a 5.7" color LCD display
- Built-in Ethernet and USB 2.0 interfaces
- Accepts voltage, thermocouple, humidity, and RTD inputs
- 20ch terminal stand with M3 screws
- 100 mS/s sampling rate max (10-ch.) to 1 h
- 20 channels - or Extension unit (max 200 ch)
- 12 mb internal flash memory
- USB memory slot is standard
- Multifunction inputs (20mV to 50V FS, Pt100 RTD's, & 4-20 mA via shunt)
- High input isolation is built-in! Enhanced safety and ease of connection.
- Selectable between Pulse and Logic, Number of channels:4
- Ultra small A5 size (232mm × 152mm × 50mm)
|
Description
|
Expandable from the standard 20-channel configuration to a maximum of 200 channels. All channels feature insulated and multi-function inputs
The GL800 is a compact data logger, with an A5 footprint, providing excellent portability. All channels are isolated channel-to-channel and channel-to-ground. It has the ability to perform simultaneous measurement of voltage , temperature and humidity. It also supports such inputs as pulse (e.g. power, rpm and flow) and logic, in addition to voltage and temperature.
Large TFT display
The 5.7-inch TFT display is bright and easy to read, with a choice of three screens to suit the measurement application. The settings screen shows the input signal waveform in order to illustrate the impact of each modification in real time.
The LOGGER operates on both AC and DC, as well as on battery power supplied via twin on- board batteries designed to allow nine hours of continuous operation. *2
The LOGGER has been designed to provide maximum protection for important measurement data, by switching automatically to battery back-up in the event of an interruption to the AC power supply, and stopping measurement and closing all files when the battery power is low.
Record directly to USB memory
The new LOGGER is compatible with high-capacity USB memory devices and also features 12 MB of internal flash memory.
Transfer data easily via USB or Ethernet; use Ethernet web server and FTP features for remote monitoring
LOGGER is equipped with a user-friendly USB interface for simple connection to an external computer and Ethernet for remote monitoring.
Fast and easy connection to external computer
USB 2.0 makes it easy to connect to a computer for real-time transfer of sampling data at up to 100 ms, while LAN connectivity supports remote monitoring applications and USB memory supports offline data transfer.
Safe and simple
Key lock and password authentication
The key lock feature has been supplemented with password the key lock feature has been supplemented with password authentication to prevent operational errors, particularly in applications where the system may be unattended for extended periods.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| GL800 |
GL800 midi LOGGER Mainframe - Ultra-data logger with high isolation, 20 channels standard - upgradeable up to 200 channels, Ethernet and USB 2.0 computer interfaces standard, Network ready, USB Flash memory slot for data archival, Bright 5.7" color TFT LCD display and easy user interface, Multifunction inputs (20mV to 50V FS, various thermocouple types, Pt100 RTD's, & 4-20 mA via shunt), Sampling as fast as 100 ms, or as slow as 1/hour, Runs from AC (standard), DC (standard) or battery (optional) |
$1995.00 |
| $1955.10 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| RIC-141 |
Please call or email us for pricing and availability. |
| RIC-112 |
BNC-BNC cable, 6 ft |
$35.00 |
| $34.30 |  |
|
| RIC-113 |
BNC-Banana cable, 6 ft |
$36.00 |
| $35.28 |  |
|
| RIC-114 |
BNC-Alligator Clips cable, 6 ft |
$27.00 |
| $26.46 |  |
|
| B-517 |
Battery pack (installs within the mainframe, powers the system for approximately 6 hours with two batteries) |
$120.00 |
| $117.60 |  |
|
| B-513 |
Cable: 4 x Logic inputs & 4 x alarm outputs, 2 meters |
$80.00 |
| $78.40 |  |
|
| B-514 |
DC power cable, 2 meters, bare ends, for direct connection to DC power source |
$50.00 |
| $49.00 |  |
|
| B-536 |
Midi Logger carrying case for GL200 / GL800 |
$400.00 |
| $392.00 |  |
|
| B-530 |
Humidity sensor, 0 to 100% RH |
$400.00 |
| $392.00 |  |
|
| RIC-410 |
Please call or email us for pricing and availability. |
| RIC-420 |
Please call or email us for pricing and availability. |
| RIC-430 |
Please call or email us for pricing and availability. |
Specifications
| Number of analog input terminal units |
1 unit (20 ch) or Extension unit (max. 200 ch)
Maximum 10 units or 200 ch when using with a PC |
| Sampling interval*1 |
Current |
100 ms (10 ch) to 1 h |
| Trigger Function |
Type |
Start (Data capture starts when a trigger is generated)
Stop (Data capture stops when a trigger is generated)
|
| Condition |
Start: Off, Level, Alarm, Scheduled Time, External
Stop: Off, Level, Alarm, Scheduled Time, Elapsed Time, External |
| Alarm |
Type |
Analog, Logic, Pulse (AND and OR operations available) |
| Condition |
Analog: H, L, Window In, Window Out |
| Logic: H, L, at each channel |
| Pulse: H, L, Window In, Window Out |
| Pulse/Logic input |
Selectable between Pulse and Logic.
Number of channels: 4 |
| Pulse input range |
Count mode |
50 c, 500 c, 5 kc, 500 kc, 5MC, 50MC, 500MC/F.S. (max. 50 k/sampling interval) |
| Inst. mode |
50 c, 500 c, 5 kc, 500 kc, 5MC, 50MC, 500MC/F.S. (max. 50 k/sampling interval) |
| RPM mode |
50 rpm, 500 rpm, 5 krpm, 50 krpm, 500krm, 5Mrpm, 50Mrpm, 500Mrpm/F.S. (max. 50k/sec) |
| Alarm output |
Number of channels |
4 ch |
| Output format |
Open collector output (5 volt pull-up resistance 10 k ohm), 5 to 24 v (100mA or less) |
| Output conditions |
Level judgment, Window judgment, Logic Pattern judgment, Pulse judgment |
| External trigger input *2 *5 |
1 ch |
| Interface to PC |
Ethernet (10BASE-T/100BASE-TX), USB (Compatible with high-speed) |
| Internal memory |
12 MByte |
| PCMCIA slot |
Type 2 compatible |
| Calculation Function |
Statistics calculation |
Avereage, Peak, Maximum, Minimum, RMS
|
| Number of Calculations |
2 calculations can be set simultaneously |
| Display |
Size |
5.7-inch TFT color LCD |
| Displayed items |
Waveforms + digital values, waveforms only, digital values only |
| Operating environment |
Temperature: 0 - 45°C (15 - 40°C when operating by battery) , Humidity 5 - 85% RH |
| Searching Function |
Searching the bneccesary point captured data. Type: Level, Alarm, Logic, Pulse
|
| Power supply |
AC adapter (100 to 240 VAC, 50/60Hz) DC power (8.5 to 24 VDC) *3 Battery pack: Max 2 batteries installable, 9 hours operation (when using under Graphtec specified condition) |
| Power consumption |
26 VA or lower (AC power) |
| External dimensions (W x D x H, approx.) |
232x 152 x 50mm |
| Weight (approx.) |
990 g including a 20 channel input terminal unit *4 |
| Vibration resistance |
Compatible with JIS vibration testing methods for auomobile Type 1 Class A-Equivalent |
| Certifications |
CE, RoHS,China RoHS |
*1 The available number of channels varies according to the sampling interval
*2 Maximum input voltage: 24 V, input threshold voltage: approx. 2.5V, hysteresis: approx. 0.5V (+2.5 to +V)
*3 Optional
*4 Excluding the battery and AC adapter
#5 Logic/Alarm cable (B-513) is required |
GL800 Input Terminal Unit Specifications
| Number of input channels |
20 (maximum 200 channels by the expansion terminal unit) |
| Type of input terminal |
M3 screw type terminal |
| Method |
Scan All channels isolated, Non balanced input |
| Measurment Range |
Voltage |
20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50V, 1-5 V F.S
|
| Temperature |
Thermocouple : K, J, E, T, R, S, B, N, W (WRe5-26) RTD : Pt100, JPt100, Pt1000 (IEC751 |
| Humidity |
0 to 100 % RH (Voltage 0 to 1 V conversion, when optional B-530 humidity sensor is used) |
| Input filter |
Off, 2, 5, 10, 20, 40 (Moving average) |
Measurement Accuracy (23? ± 5?) When 30minutes or more have elapsed after power was switched on Sampling 1s/20ch Filter ON(10) GND connected |
Voltage |
± 0.1 % of F.S. |
| Temperature |
Measurement range |
Accuracy |
| Thermocouple |
R/S |
0 ≤ TS ≤100 °C |
± 5.2 °C |
| |
100 < TS ≤300 °C |
± 3.0 °C |
| |
R : 300 < TS ≤1600 °C |
± (0.05 % of rdg + 2.0 °C) |
| |
S : 300 < TS ≤1760 °C |
± (0.05 % of rdg + 2.0 °C) |
| B |
400 ≤ TS ≤ 600 °C |
± 3.5 °C |
| |
600 < TS ≤ 1820 °C |
± (0.05 % of rdg + 2.0 °C) |
| K |
-200 ≤ TS ≤-100 °C |
± (0.05 % of rdg + 2.0 °C) |
| |
-100 < TS ≤1370 °C |
± (0.05 % of rdg + 1.0 °C) |
| E |
-200 ≤ TS ≤-100 °C |
± (0.05 % of rdg + 2.0 °C) |
| |
-100 < TS ≤800 °C |
± (0.05 % of rdg + 1.0 °C) |
| T |
-200 ≤ TS ≤ -100 °C |
± (0.1 % of rdg + 1.5 °C) |
| |
-100 < TS ≤400 °C |
± (0.1 % of rdg + 0.5 °C) |
| J |
-200 ≤ TS ≤ -100 °C |
± 2.7 °C |
| |
-100 ≤ TS ≤100 °C |
± 1.7 °C |
| |
100 < TS ≤1100 °C |
± (0.05 % of rdg + 1.0 °C) |
| N |
0 ≤ TS ≤1300 °C |
± (0.1 % of rdg + 1.0 °C) |
| W |
0 ≤ TS ≤2315 °C |
± (0.1 % of rdg + 1.5 °C) |
| * If the reference junction compensation is internal, add ± 0.5 °C to each of the above values. |
| RTD |
Pt100 |
-200 to 850 °C (FS = 1050 °C) |
± 1.0 °C |
| JPt100 |
-200 to 500 °C (FS = 700 °C) |
± 0.8 °C |
| Pt1000 |
-200 to 500 °C (FS = 700 °C) |
± 0.8 °C |
| A/D converter |
16 bit (out of which 14 are internally acknowledged) |
| Maximum input voltage |
60 Vp-p (Between ±) |
| 60 Vp-p (Between input terminals) |
| 60 Vp-p (Between input terminal and chassis) |
| Withstand voltage |
350 Vp-p (between input terminal and GND) 1 minute |
|